Fabrication of embedded microball lens in PMMA with high repetition rate femtosecond fiber laser Chong Zheng,1,2 Anming Hu,1,2,* Ruozhou Li,2,3 Denzel Bridges,2 and Tao Chen1,4 1

Institute of Laser Engineering, Beijing University of Technology, Pingleyuan 100, Chaoyang District, Beijing 100124, China Department of Mechanical, Aerospace and Biomedical Engineering, University of Tennessee, Knoxville, Tennessee 37996, USA 3 School of Electronic Science and Engineering, Southeast University, Key Laboratory of Micro-Inertial Instrument and Advanced Navigation Technology, Ministry of Education, Nanjing 210096, China 4 [email protected] * [email protected]

2

Abstract: Embedded microball lenses with superior optical properties function as convex microball lens (VMBL) and concave microball lens (CMBL) were fabricated inside a PMMA substrate with a high repetition rate femtosecond fiber laser. The VMBL was created by femtosecond laserinduced refractive index change, while the CMBL was fabricated due to the heat accumulation effect of the successive laser pulses irradiation at a high repetition rate. The processing window for both types of the lenses was studied and optimized, and the optical properties were also tested by imaging a remote object with an inverted microscope. In order to obtain the microball lenses with adjustable focal lengths and suppressed optical aberration, a shape control method was thus proposed and examined with experiments and ZEMAX® simulations. Applying the optimized fabrication conditions, two types of the embedded microball lenses arrays were fabricated and then tested with imaging experiments. This technology allows the direct fabrication of microlens inside transparent bulk polymer material which has great application potential in multi-function integrated microfluidic devices. © 2015 Optical Society of America OCIS codes: (140.3390) Laser materials processing; (130.3990) Micro-optical devices; (140.3330) Laser damage; (140.7090) Ultrafast lasers; (130.3120) Integrated optics devices;

References and links 1.

2. 3. 4. 5. 6.

J. Kim, C. J. Nuzman, B. Kumar, D. F. Lieuwen, J. S. Kraus, A. Weiss, C. P. Lichtenwalner, A. R. Papazian, R. E. Frahm, N. R. Basavanhally, D. A. Ramsey, V. A. Aksyuk, F. Pardo, M. E. Simon, V. Lifton, H. B. Chan, M. Haueis, A. Gasparyan, H. R. Shea, S. Arney, C. A. Bolle, P. R. Kolodner, R. Ryf, D. T. Neilson, and J. V. Gates, “1100 x 1100 port MEMS-based optical crossconnect with 4-dB maximum loss,” IEEE. Photon. Technol. Lett. 15(11), 1537–1539 (2003). C. P. B. Siu, H. Zeng, and M. Chiao, “Magnetically actuated MEMS microlens scanner for in vivo medical imaging,” Opt. Express 15(18), 11154–11166 (2007). J. Arai, H. Kawai, and F. Okano, “Microlens arrays for integral imaging system,” Appl. Opt. 45(36), 9066–9078 (2006). Y. M. Song, Y. Xie, V. Malyarchuk, J. Xiao, I. Jung, K. J. Choi, Z. Liu, H. Park, C. Lu, R. H. Kim, R. Li, K. B. Crozier, Y. Huang, and J. A. Rogers, “Digital cameras with designs inspired by the arthropod eye,” Nature 497(7447), 95–99 (2013). J. C. Roulet, R. Völkel, H. P. Herzig, E. Verpoorte, N. F. de Rooij, and R. Dändliker, “Performance of an integrated microoptical system for fluorescence detection in microfluidic systems,” Anal. Chem. 74(14), 3400– 3407 (2002). Y. Y. Sun, L. S. Ong, and X. C. Yuan, “Composite-microlens-array-enabled microfluidic sorting,” Appl. Phys. Lett. 89(14), 141108 (2006).

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17584

7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34.

J. C. Roulet, R. Volkel, H. P. Herzig, E. Verpoorte, N. F. de Rooij, and R. Dandliker, “Fabrication of multilayer systems combining microfluidic and microoptical elements for fluorescence detection,” J. Microelectromech. Syst. 10(4), 482–491 (2001). F. B. McCormick, F. A. P. Tooley, T. J. Cloonan, J. M. Sasian, H. S. Hinton, K. O. Mersereau, and A. Y. Feldblum, “Optical interconnections using microlens arrays,” Opt. Quantum Electron. 24(4), S465–S477 (1992). E. H. Park, M. J. Kim, and Y. S. Kwon, “Microlens for efficient coupling between LED and optical fiber,” IEEE Photon. Technol. Lett. 11(4), 439–441 (1999). J. W. Pan, C. M. Wang, H. C. Lan, W. S. Sun, and J. Y. Chang, “Homogenized LED-illumination using microlens arrays for a pocket-sized projector,” Opt. Express 15(17), 10483–10491 (2007). R. Winston, P. Schreiber, S. Kudaev, P. Dannberg, U. D. Zeitner, and R. J. Koshel, “Homogeneous LEDillumination using microlens arrays,” Proc. SPIE 5942, 59420K (2005). G. Schlingloff, H. J. Kiel, and A. Schober, “Microlenses as amplification for CCD-based detection devices for screening applications in biology, biochemistry, and chemistry,” Appl. Opt. 37(10), 1930–1934 (1998). N. Ma, P. C. Ashok, D. J. Stevenson, F. J. Gunn-Moore, and K. Dholakia, “Integrated optical transfection system using a microlens fiber combined with microfluidic gene delivery,” Biomed. Opt. Express 1(2), 694–705 (2010). P. Nussbaum, R. Völkel, H. P. Herzig, M. Eisner, and S. Haselbeck, “Design, fabrication and testing of microlens arrays for sensors and microsystems,” Pure Appl. Opt. 6(6), 617–636 (1997). Q. Dai, R. Rajasekharan, H. Butt, X. Qiu, G. Amaragtunga, and T. D. Wilkinson, “Ultrasmall microlens array based on vertically aligned carbon nanofibers,” Small 8(16), 2501–2504 (2012). Z. Wang, W. Guo, L. Li, B. Luk’yanchuk, A. Khan, Z. Liu, Z. Chen, and M. Hong, “Optical virtual imaging at 50 nm lateral resolution with a white-light nanoscope,” Nat. Commun. 2, 218 (2011). Y. Yan, L. Li, C. Feng, W. Guo, S. Lee, and M. Hong, “Microsphere-coupled scanning laser confocal nanoscope for sub-diffraction-limited imaging at 25 nm lateral resolution in the visible spectrum,” ACS Nano 8(2), 1809– 1816 (2014). Y. J. Fan, Y. C. Wu, Y. Chen, Y. C. Kung, T. H. Wu, K. W. Huang, H. J. Sheen, and P. Y. Chiou, “Three dimensional microfluidics with embedded microball lenses for parallel and high throughput multicolor fluorescence detection,” Biomicrofluidics 7(4), 044121 (2013). M. A. Burns, B. N. Johnson, S. N. Brahmasandra, K. Handique, J. R. Webster, M. Krishnan, T. S. Sammarco, P. M. Man, D. Jones, D. Heldsinger, C. H. Mastrangelo, and D. T. Burke, “An integrated nanoliter DNA analysis device,” Science 282(5388), 484–487 (1998). Y. Cheng, K. Sugioka, K. Midorikawa, M. Masuda, K. Toyoda, M. Kawachi, and K. Shihoyama, “Threedimensional micro-optical components embedded in photosensitive glass by a femtosecond laser,” Opt. Lett. 28(13), 1144–1146 (2003). Y. Cheng, H. L. Tsai, K. Sugioka, and K. Midorikawa, “Fabrication of 3D microoptical lenses in photosensitive glass using femtosecond laser micromachining,” Appl. Phys., A Mater. Sci. Process. 85(1), 11–14 (2006). A. A. Bettiol, C. N. B. Udalagama, E. J. Teo, J. A. van Kan, and F. Watt, “Embedded photonic structures fabricated in photosensitive glass using proton beam writing,” Nucl. Instrum. Methods Phys. Res. Sect. B 260, 357–361 (2007). J. M. Fernández-Pradas, D. Serrano, P. Serra, and J. L. Morenza, “Laser fabricated microchannels inside photostructurable glass-ceramic,” Appl. Surf. Sci. 255(10), 5499–5502 (2009). Y. Kondo, J. Qiu, T. Mitsuyu, K. Hirao, and T. Yoko, “Three-dimensional microdrilling of glass by multiphoton process and chemical etching,” Jpn. J. Appl. Phys. 38(Part 2, No. 10A), L1146–L1148 (1999). D. J. Hwang, T. Y. Choi, and C. P. Grigoropoulos, “Liquid-assisted femtosecond laser drilling of straight and three-dimensional microchannels in glass,” Appl. Phys., A Mater. Sci. Process. 79(3), 605–612 (2004). K. C. Vishnubhatla, N. Bellini, R. Ramponi, G. Cerullo, and R. Osellame, “Shape control of microchannels fabricated in fused silica by femtosecond laser irradiation and chemical etching,” Opt. Express 17(10), 8685– 8695 (2009). Y. Li and S. Qu, “Water-assisted femtosecond laser ablation for fabricating three-dimensional microfluidic chips,” Curr. Appl. Phys. 13(7), 1292–1295 (2013). S. Juodkazis, S. Matsuo, H. Misawa, and K. Yamasaki, “Three-dimensional micro-channels in polymers: onestep fabrication,” Appl. Phys., A Mater. Sci. Process. 77(3-4), 371–373 (2003). D. F. Farson, H. W. Choi, C. M. Lu, and L. J. Lee, “Femtosecond laser bulk micromachining of microfluid channels in poly(methylmethacrylate),” J. Laser Appl. 18(3), 210–215 (2006). Y. Ishii, S. Koike, Y. Arai, and Y. Ando, “Ink-jet fabrication of polymer microlens for optical-I/O chip packaging,” Jpn. J. Appl. Phys. 39(1), 1490–1493 (2000). M. He, X. C. Yuan, N. Q. Ngo, J. Bu, and V. Kudryashov, “Simple reflow technique for fabrication of a microlens array in solgel glass,” Opt. Lett. 28(9), 731–733 (2003). A. Schilling, R. Merz, C. Ossmann, and H. P. Herzig, “Surface profiles of reflow microlenses under the influence of surface tension and gravity,” Opt. Eng. 39(8), 2171–2176 (2000). N. S. Ong, Y. H. Koh, and Y. Q. Fu, “Microlens array produced using hot embossing process,” Microelectron. Eng. 60(3-4), 365–379 (2002). Z. D. Popovic, R. A. Sprague, and G. A. N. Connell, “Technique for monolithic fabrication of microlens arrays,” Appl. Opt. 27(7), 1281–1284 (1988).

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17585

35. M. Malinauskas, A. Žukauskas, V. Purlys, K. Belazaras, A. Momot, D. Paipulas, R. Gadonas, A. Piskarskas, H. Gilbergs, A. Gaidukevičiūtė, I. Sakellari, M. Farsari, and S. Juodkazis, “Femtosecond laser polymerization of hybrid/integrated micro-optical elements and their characterization,” J. Opt. 12(12), 124010 (2010). 36. D. Wu, J.-N. Wang, L.-G. Niu, X. L. Zhang, S. Z. Wu, Q.-D. Chen, L. P. Lee, and H. B. Sun, “Bioinspired fabrication of high-quality 3D artificial compound eyes by voxel-modulation femtosecond laser writing for distortion-free wide-field-of-view imaging,” Adv. Opt. Mater. 2(8), 751–758 (2014). 37. F. Chen, H. Liu, Q. Yang, X. Wang, C. Hou, H. Bian, W. Liang, J. Si, and X. Hou, “Maskless fabrication of concave microlens arrays on silica glasses by a femtosecond-laser-enhanced local wet etching method,” Opt. Express 18(19), 20334–20343 (2010). 38. Y. Hu, Q. Yang, F. Chen, H. Bian, Z. Deng, G. Du, J. Si, F. Yun, and X. Hou, “Cost-efficient and flexible fabrication of rectangular-shaped microlens arrays with controllable aspect ratio and spherical morphology,” Appl. Surf. Sci. 292, 285–290 (2014). 39. C. H. Lin, L. Jiang, Y. H. Chai, H. Xiao, S. J. Chen, and H. L. Tsai, “Fabrication of microlens arrays in photosensitive glass by femtosecond laser direct writing,” Appl. Phys., A Mater. Sci. Process. 97(4), 751–757 (2009). 40. D. Wu, J. Xu, L.-G. Niu, S.-Z. Wu, K. Midorikawa, and K. Sugioka, “In-channel integration of designable microoptical devices using flat scaffold-supported femtosecond-laser microfabrication for coupling-free optofluidic cell counting,” Light Sci. Appl. 4(1), e228 (2015). 41. C. Zheng, A. Hu, K. D. Kihm, Q. Ma, R. Li, T. Chen, and W. W. Duley, “Femtosecond laser fabrication of cavity microball lens (CMBL) inside a PMMA substrate for super-wide angle imaging,” Small (2015), http://www.ncbi.nlm.nih.gov/pubmed/25740653. 42. R. Buividas, S. Rekštytė, M. Malinauskas, and S. Juodkazis, “Nano-groove and 3D fabrication by controlled avalanche using femtosecond laser pulses,” Opt. Mater. Express 3(10), 1674–1686 (2013). 43. S. Eaton, H. Zhang, P. Herman, F. Yoshino, L. Shah, J. Bovatsek, and A. Arai, “Heat accumulation effects in femtosecond laser-written waveguides with variable repetition rate,” Opt. Express 13(12), 4708–4716 (2005). 44. Y. Bellouard and M. O. Hongler, “Femtosecond-laser generation of self-organized bubble patterns in fused silica,” Opt. Express 19(7), 6807–6821 (2011). 45. A. Baum, P. J. Scully, W. Perrie, D. Liu, and V. Lucarini, “Mechanisms of femtosecond laser-induced refractive index modification of poly (methyl methacrylate),” J. Opt. Soc. Am. B 27(1), 107–111 (2010). 46. M. Ferriol, A. Gentilhomme, M. Cochez, N. Oget, and J. Mieloszynski, “Thermal degradation of poly (methyl methacrylate)(PMMA): modelling of DTG and TG curves,” Polym. Degrad. Stabil. 79(2), 271–281 (2003). 47. A. Hu, M. Rybachuk, Q. B. Lu, and W. W. Duley, “Direct synthesis of sp-bonded carbon chains on graphite surface by femtosecond laser irradiation,” Appl. Phys. Lett. 91(13), 131906 (2007). 48. H. Zappe, Fundamentals of Micro-Optics (Cambridge University, 2010).

1. Introduction Recent researches have demonstrated that microlenses (ML) and microlens arrays (MLA) are powerful optical components that have already been utilized in diverse applications, e.g. microelectromechanical systems (MEMS) [1,2], wide field/3D imaging systems [3,4], microfluidic devices [5–7], optical connectors [8], light-emitting diodes (LEDs) [9–11], charge-coupled devices (CCDs) [12], optical fibers [9,13] and sensors [14,15]. Especially, microball lenses which are unique with their spherical shape and micrometer-scale sizes, have been proved to have great application potential in optical super-resolution imaging which a sub-diffraction limited resolution can be achieved (1.55) calculated based on the LorentzLorenz equation in our previous study [41]. The fabricated structure thus can optically functions as a concave microball lens (CMBL).

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17589

Fig. 2. The structural development of microlenses with different average power. (a) A melted region is generated accompanied with cracks at the center of the ablated region (30 mW, 1.8 × 1013W/cm2). (b) and (c) shows nonuniform affected zones are created with sharp edges (50 mW, 3.0 × 1013W/cm2) and will be smoother if further increase the average power (70 mW, 4.2 × 1013W/cm2). (d) A uniform and symmetric VMBL is generated (90 mW, 5.4 × 1013W/cm2). (e) A bubble is generated and formed a cavity at the edge of the affected zone (130 mW, 7.8 × 1013W/cm2). (f) and (g) shows bubble is generated nonuniformly with insufficient energy (150 mW ~170 mW, 9.1 × 1013W/cm2 ~1.0 × 1014W/cm2). (h) Symmetric CMBL is generated when average power reaches 400 mW (2.4 × 1014 W/cm2).

As the fabrication of VMBL has a relatively narrow processing window, the best result shows that a proper average power is 90 mW. Here we mainly focused on the optimization of the experimental conditions to fabricate the CMBLs with the best properties by changing the average laser power (Fig. 3). As illustrated above, with laser average power above 200 mW at a repetition rate of 120 kHz irradiated for 5s, micro bubbles can be generated inside a PMMA substrate that provides the possibility to fabricate a CMBL. Nevertheless, the bubble is shaped nonuniformly and located randomly if irradiated with insufficient laser power (< 400 mW). When the average power is increased to 0.4 ~1.5 W (corresponding peak power density ranging from 2.4 × 1014 W/cm2 to 9.1 × 1014 W/cm2), spherical micro-bubble with supersmooth surface can be acquired at the irradiated region which forms the CMBL after the melted region is resolidified. The diameter of the fabricated CMBL displayed a near-linear increase with the average power at a rate of 5.52 μm/ 100 mW. Whereas the optical properties were ruined if the average power exceed 1.5 W when an over-ablated CMBL with dark brown polymer-like matters covers on the surface of the fabricated spherical cavity. These dark brown materials should come from femtosecond laser induced high temperature high pressure conduction and multi-photon decomposition of polymer [47].

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17590

Fig. 3. Development of the CMBL sizes when increasing the average laser power. The inset figures shows with processing window for a symmetric CMBL is from 400 mW to 1.5 W (2.4 × 1014 W/cm2 ~9.1 × 1014 W/cm2), otherwise an aspherical cavity or over-ablated CMBL will generated if the laser average power is insufficient or excessive.

3.2. Refractive index change of VMBL after fabrication The dimension of the fabricated VMBL is found slightly increased with the cooling time as shown in Fig. 4. The initial diameter of the VMBL after fabrication is 57 μm which grows to 63.5 μm after cooling in room temperature for 80 min. The increase of the diameter is 11.4%. While according to the imaging experiment of the lightened dark field mask with a VMBL as aforementioned, the dimension of the image increased from 78.2 μm to 110.5 μm in which the increase reaches 41.3%. The results show that although there is a slight diameter increase of the VMBL during the cooling process after irradiation, the increase of the image captured by this VMBL is much larger than the diameter increase of the fabricated VMBL. This is mainly because of the stress release caused by the heat diffusion during the slowly cooling process. Highly concentrated heat due to the heat accumulated effect of the fs laser pulses will diffuse to the ambient when the laser irradiation process is finished. The central temperature will then slowly decreases until cooling down to the room temperature. Stress induced by the laser irradiation thus partially released with the cooling process and results in the refractive index decrease of the fabricated VMBL. As a consequence, the size of the image captured by the VMBLs in the similar sizes increases with the cooling time.

Fig. 4. The dimension developments of VMBL and its image with the cooling time. (a) shows that the diameter of VMBL slightly increased after cooling for 80 min, meanwhile the image taken by the cooled VMBL shows distinguished increase. (b) illustrates the diameter development of VMBL and its image with the cooling time.

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17591

3.3. Telescopic imaging with microball lens To simply examine the optical functions of both types of microlenses, a micro-telescopic imaging system is constructed with a PMMA substrate containing an embedded microball lens (both the VMBL and the CMBL) and a microscopic objective lens as illustrated in Fig. 5(a). An illuminated dark field mask of the inverted microscope is used as an object to be viewed with this micro-telescopic imaging system. Figure 5(b) shows the image taken with a VMBL as the front lens of the micro-telescope in which the shape and details of the mask are perfectly recorded. However, when imaging with a CMBL as in Fig. 5(c), the image of mask is much smaller and blurred. These results shows that the micro-telescope constructed with a VMBL possesses higher resolution but smaller field of view (FOV); whereas, although the details cannot be distinguished with the micro-telescope constructed with a CMBL, this imaging system can provide a super wide FOV reaches ~350° according our previous study [41]. This imaging experiment illustrates that both VMBL and CMBL fabricated with fs laser irradiation possess good optical properties and great application potential.

Fig. 5. (a) A micro-telescope is constructed with microball lens and microscopic objective, enables telescopic imaging of the brightened mask as illustrated. Images captured by a microtelescopic system with the front lens of (b) VMBL or (c) CMBL.

3.4. Shape control of microball lens fabrication As the CMBL are fabricated approximate to spherical cavity, it naturally possesses numerous aberration due to its shape [48]. To reduce these aberrations and fabricate microball lens with adjustable focal lengths for different applications, we purpose a method called the shape control method by scanning the PMMA substrate along a certain direction with different speeds. As illustrated in Figs. 6(a) and 6(c), the PMMA substrate is scanned horizontally (Xaxis or Y-axis) for 1~7 cycles in 5 s with a scanning length of 80 μm, in another word, the velocities of the 3D stage moved ranging from 32 μm/s to 224 μm/s. The fabricated CMBL is ellipsoid-shaped which proves that the shape control method can extend the length along a certain direction. The dashed line in Fig. 6(a) indicates the diameter of the CMBL without shape control in the same experimental conditions, which is 104.1 μm. The length of long axis of the ellipsoidal CMBL first increases with the number of scanning cycles (or the scanning speed) from 99.4 μm if irradiated for only 1 cycle in 5 second to the maximum length of 107.7 μm if irradiated for 4 cycles in 5 s. This value will then decreases if further increase the number of cycles to 99.6 μm when irradiated for 7 cycles. The fabricated structure will be less nonuniform or even shaped as separated bubbles when the number of the cycles is larger than 7. This will seriously degrade the optical properties of the CMBL. The shape changes of the CMBL with the increase of scanning speed can be understood like this:

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17592

(i) Low-speed scanning (32 μm/s): when the scanning speed is relatively slow, the earlier heated region will be solidified when the heat resource, the laser focus, moves to other places due to the fast heat diffusion. This solidified region will be re-melted when the laser scans back again, but the later melted region will be solidified in turn. This is the reason for a shorter length of the resulted cavity. In another hand, the volume of the generated gas during this period is limited since the heat generated from laser pulses cannot be effectively accumulated because of a relatively longer heat diffusion period. (ii) Medium-speed scanning (64μm/s ~192 μm/s): when the scanning speed is further increased, a melting pool will be maintained at the center of the irradiated region and more gas will tend to be generated because the temperature of the irradiated region is steadily sustained in a high level that is beyond the random scission temperature. As a result, more gas is released and forms an ellipsoidal cavity with its long axis along the scanning direction. (iii) High-speed scanning (≥224 μm/s): when laser scans at a speed of 224μm/s, the laser focus will immediately move out from the heated region where the temperature reaches to (or is slightly beyond) the threshold temperature of the gas generation. Thus, the amount of the released gas is limited due to the insufficient heating, which results in a smaller ellipsoidal cavity with its short axis along the scanning direction. If laser scans even faster, the heat accumulated effect will be greatly restrained. As a result, separated tiny bubbles are observed along the scanning route which cannot be precisely controlled to fabricate a single, pre-designed CMBL.

Fig. 6. Shape control of CMBL horizontally (along X-axis or Y-axis) and vertically (along Zaxis) by scanning with the laser for 1~7 cycles in 5s. (a) Scan with a 1.2 W laser power at a repetition rate 120 kHz in a scanning distance for 80 μm. (b) Scan with a 1.4 W laser power at a repetition rate 120 kHz in a scanning distance for 45 μm. (c) An X-axis shape controlled sample. (d) A Z-axis shape controlled sample.

Figures 6(b) and 6(d) shows a PMMA substrate was scanned with 1.4 W laser for 1 to 7 cycles in 5 s for a 45 μm distance. The evolution tendency is similar as discussed in Fig. 6(a)

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17593

in which the length of the cavity first increase along Z-axis with the increasing cycle numbers from 126.7 μm to 132.4 μm. Then the Z-axis dimension decrease if further increase when the cycle number >4 and reached 116.1 μm when scanned for 7 cycles in 5 s, which is much shorter than the one without Z-axis shape control (124.2 μm). The side view of this CMBL also proves that the shape control long Z-axis could be achieved with this method. Note that the laser power and the scanning distance use in the X-axis and Z-axis shape control is different in the purpose to show a better contrast to the original CMBL. The solid lines in both figures are guides to eyes. To examine the performance of a shape controlled CMBL, a letter “F” is imaged by using the aforementioned microscope-microball lens telescope system. The microball lenses used in this experiment are CMBLs fabricated without/with the Z-axis shape control, as shown in Fig. 7. The CMBL without Z-axis shape control is fabricated with a 1.2 W average power at a repetition rate of 120 kHz irradiated for 5 s. A spherical cavity is observed with a diameter of 88 μm in Fig. 7(b). While the CMBL fabricated by scanning for 4 cycles in 5s along Z-axis in the same laser conditions is shaped as an ellipsoid with a 129 μm long axis and 102 μm short axis as shown in Fig. 7(d). It is seen that with the normal CMBL in Fig. 7(a), large distortion is clearly observed, while the image taken by the one fabricated with Z-axis shape controlled CMBL is much clearer and has less aberrations.

Fig. 7. Z-axis shape control of CMBL scanning at a speed of 72 μm/s and a distance 45 μm for 4 cycles while irradiation. (a) The image of a letter “F” taken by a CMBL with a spherical cavity fabricated without Z-axis shape control. (b) The side view of the CMBL with spherical cavity. (c) The image of a letter “F” taken by a CMBL with an elliptical cavity after Z-axis shape control. (d) The side view of the CMBL with elliptical cavity.

The shape control method is explained with a ray tracing simulation taken by ZEMAX®. The optical properties of three kinds of CMBLs are compared, including: 1) one spherical cavity CMBL (Fig. 8(a)) and two elliptical cavity CMBLs (Figs. 8(b) and 8(c)) whose axis along the Z-direction is 2) longer or 3) shorter than the radius of the spherical cavity. The radius for the spherical cavity of CMBL is set as Ra1 = 50 μm and covered with a refractive index changed PMMA shell (n = 1.55) whose radius Ra2 = 100 μm (e.g. thickness T = 50 μm). In addition, since the significant dimension change of the Z-axis shape control is occurred along the Z-axis direction, for the elliptical CMBLs in Figs. 8(b) and 8(c), the length along Zaxis is supposed to be the same as the radius of the spherical cavity, e.g. b1 (or a2) = 50 μm. Thus, we set these two comparison experiment with elliptical CMBL with Z-axis length at b)

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17594

a1 = 60 μm and c) b2 = 40 μm, respectively. The covered shell is assumed at the same thickness 50 μm. The radius of curvature ρ at the tips of the long-axis of the ellipse is calculated by ρ = b2/a, where a represents the length of long-axis, b represents the length of the short-axis of the ellipse. Note that it changes to ρ = a2/b when calculating the radius curvature at the tips of the short-axis. In this simulation, rays transmit from with three different angles 0°, 20° and −20° are focused on the image plane with an objective lens. The best focused geometric images of the letter “F” taken with CMBL 1), 2) and 3) are shown in Figs. 8(d) and 8(f), respectively. To further illustrate the distortion caused by each CMBL, the distortion curves are given as Figs. 8(g)-8(i). According to Figs. 8(d) and 8(g), the spherical CMBL suffers from large positive distortion, which make is seems as a pillow. The maximum distortion is almost reaches 60%. While the elongated CMBL proves that it can reduce the distortion to 40% and makes the letter “F” looks more uniform. Note that all the distortion curves of different wavelengths are in positive range in Figs. 8(g) and 8(h). However, it can be clearly seen that the distortion got some negative value at the higher positions (larger Y value) when the CMBL is shorter along Z-axis. Thus, even though part of the curves are still in the positive range, the slightly distortion which is lower than 12% is not that distinguishable when using for imaging. These results show that the shape control method is a proven method to reduce the aberrations. Besides, the effective focal length (EFL) for the original spherical CMBL is −32.8 μm. It changes to −23.73 μm when the cavity is elongated along the Z-axis direction for 20 μm and varied to −46.5um when it is shorted for 20 μm. Thus, this method is also possible for making CMBLs with different EFLs that is very important in internal microlens fabrication.

Fig. 8. Optical properties of CMBL with different shapes. (a) ~(c) Spherical cavity CMBL and elliptical cavity CMBLs; (d) ~(f) The geometric image of a letter “F”; (g) ~(i) The distortion curves when imaging with different CMBLs. The colorful curves represents the distortion curve of the incident light with different wavelengths, in which the blue light (484 nm), the green light (588 nm), and red light (656 nm) are represented by the curves with the same color.

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17595

3.5. Propagation of the stress wavefront and annealing During the irradiation process, a wavefront is observed propagating when the cavity is gradually forming and increasing the size as shown in Fig. 9. It is generated once the laser pulses irradiated on the PMMA substrate and spread quickly ahead the growing melting region. This wavefront is believed as a result of the concentrated stresses generated due to the gas expansion and thermal expansion act on the softened region outside the melting pool, thus it is denominated here as “stress wavefront”.

Fig. 9. Snap shot of the stress wavefront propagation process.

The stress wavefront has great influence when a fabricate microball lens array. As illustrated in Fig. 10(a), the boundary of a prior made CMBL (right) is compressed by the stress wavefront generated when fabricating the second CMBL (left), thus affected the uniformity of a microball lens array. As the deformation is caused by the residual stress, the CMBL array is then annealed in the purpose to diminish the stress. The result shows that the deformation is successfully cured after annealing in the oven at 90°C for 20 min. In addition, it is also found that despite the distance of microball lens keep unchanged, the diameter of cavity is increased from 112 μm to 139 μm. Meanwhile, the defects at the boundary of the cavity is disappeared thus lower internal surface roughness is obtained (Fig. 10(b)). To investigate the annealing process, CMBLs are annealed in 70°C, 80°C, 90°C and 100°C for 20 min, 40 min and 60 min (Fig. 10(c)). The annealing temperatures are chosen around the Vicat softening point of PMMA (105°C). The results show that a better annealing time for a CMBL sample is 20 min. The diameter of the annealed CMBL remained almost constant even though annealed for longer time. Larger CMBL diameter can be achieved with higher annealing temperature, however, the CMBL structure will be totally destroyed if annealed with 100°C for 20 min as shown in Fig. 10(d).

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17596

Fig. 10. (a) The boundary deformation caused by the stress wavefront. The defects are partially cured and the boundary of the fabricated CMBL is smoother. (b) The diameters of the cavity regions (CR) and the affected zones (AZ) develop with different annealing temperature ranging from 70 °C to 90 °C. (c) The CMBL sample annealed in 100 °C.

3.6. Imaging with microball lens array Finally, VMBL and CMBL microlens arrays are fabricated and tested with imaging experiments. The 5 × 4 CMBL array is fabricated with a 1.4 W laser at a repetition rate of 120 kHz irradiate for 5 s. The center distance of the adjacent two CMBLs is 400 μm to avoid the affection caused by the stress wavefront. The whole process can be completed within 2 minutes, demonstrating its application potential in fabricating large area microlens arrays. The fabricated CMBL array is then applied to image the word “UT” (represents University of Tennessee) which is written in the size of 2.2 mm × 1.2 mm and located 0.1 mm above the PMMA substrate, as shown in Fig. 11(a). Some selected images taken by this array at different CMBLs were given in the inset images (i) ~(iv). Although suffered from the image distortion especially at the boundary of the cavity, it is seen that each of the CMBL has a clear field of view larger than 110°. The CMBL array can be another choice to for wide angle imaging. Similarly, a 4 × 3 VMBL array is fabricated with a 90 mW average power at a repetition rate of 120 kHz irradiate for 5 s. This array is used to image the aforementioned lightened ring mask (Fig. 11(b)) and a “UT” word (Fig. 11(c)). Although the contrast between the image and the background color is not sharp enough, the shape of the objects can be clearly imaged in CCD. This illustrates that our femtosecond fiber laser processing technique is a proven and facile method to realize internal microlens fabrication in PMMA.

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17597

Fig. 11. (a) Imaging of the word “UT” with 5 × 4 CMBL array. (b) Imaging of a lightened ring mask with a 4 × 3 VMBLs array. (c) A Letter “UT” is imaged with this VMBL array.

4. Conclusion In this paper, we successfully fabricated two types of embedded microlens function as VMBLs and CMBLs with a femtosecond fiber laser at a repetition rate of 120 kHz irradiated for 5s which was focused by a 50 × objective. The proper processing window to fabricate VMBL is 90 mW and 400 mW ~1.5 W to fabricate CMBLs. The refractive index change of the VMBL is due to the release of residual stress. Then the optical performance of the VMBL and CMBL were tested with the telescopic imaging by integrating with an inverted microscope. The imaging details show that CMBL is more suitable for wide angle imaging. The aberrations caused by the spherical shape can be partially reduced according to the shape control method, proved by both the experiment and the ZEMAX simulations. The stress wavefront caused by the spreading stresses will induce the boundary deformations of CMBL array, but it can be cured by annealing at 70°C ~90°C for 20 min. Finally a 5 × 4 CMBL array and a 4 × 3 VMBL array were fabricate and used to image remote objects. The presented technique is proved to a powerful protocol to fabricate internal microlenses in PMMA, which is of great application prospect in integrated multifunctional biochemical or electromechanical microdevices. Acknowledgements The authors gratefully acknowledge the financial support from the National Natural Science Foundation of China (Grant 50875007), the Ministry of Science and Technology of China Major Project of Scientific Instruments and Equipment Development (Grant 2011YQ030112), Key Projects of Science and Technology of Beijing Municipal Commission of Education (Grant KZ201210005009 and KZ201410005001), the Beijing Natural Science Foundation (Grant 4132017), the Beijing high level overseas talent project and the international exchange grant of the graduate school of Beijing Institute of Technology. In addition, we appreciate the research initiative funding provided by the University of Tennessee as a new hire package.

#238114 © 2015 OSA

Received 17 Apr 2015; revised 20 Jun 2015; accepted 21 Jun 2015; published 26 Jun 2015 29 Jun 2015 | Vol. 23, No. 13 | DOI:10.1364/OE.23.017584 | OPTICS EXPRESS 17598

Fabrication of embedded microball lens in PMMA with high repetition rate femtosecond fiber laser.

Embedded microball lenses with superior optical properties function as convex microball lens (VMBL) and concave microball lens (CMBL) were fabricated ...
7MB Sizes 1 Downloads 6 Views