Intraocular pressure fluctuation and glaucoma progression: what do we know? Matthew C Leidl,1 Catherine J Choi,2 Zeba A Syed,3 Samir A Melki2,3,4,5 1

Nassau University Medical Center, East Meadow, New York, USA 2 Massachusetts Eye & Ear Infirmary, Harvard Medical School, Boston, Massachusetts, USA 3 Harvard Medical School, Boston, Massachusetts, USA 4 Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA 5 Boston Eye Group, Boston, Massachusetts, USA Correspondence to Dr Samir Melki, Boston Eye Group, 1101 Beacon Street, Brookline, MA 02446, USA; [email protected] Received 8 July 2013 Revised 11 November 2013 Accepted 17 February 2014

ABSTRACT While mean intraocular pressure (IOP) has long been known to correlate with glaucomatous damage, the role of IOP fluctuation is less clearly defined. There is extensive evidence in the literature for and against the value of short-term and long-term IOP fluctuation in the evaluation and prognosis of patients with glaucoma. We present here the arguments made by both sides, as well as a discussion of the pitfalls of prior research and potential directions for future studies. Until a reliable method is developed that allows for constant IOP monitoring, many variables will continue to hinder us from drawing adequate conclusions regarding the significance of IOP variation. INTRODUCTION Intraocular pressure (IOP) is a significant factor in the diagnosis and management of glaucomatous disease. There is a well-established link between elevations in IOP and visual field (VF) deterioration, and lowering IOP may both slow this progression.1–4 and improve the appearance of glaucomatous optic discs.5 6 There are numerous methods for monitoring IOP, though the Goldmann applanation tonometer is likely the most frequently used. The device measures the amount of force required to flatten a section of the cornea, thereby indirectly calculating the IOP.7 A more in-depth discussion of tonometry is beyond the scope of this paper, though Stamper provides an excellent, highly recommended discussion of the topic. Studies show that IOP tends to fluctuate throughout the day and over longer intervals.8–12 It has been difficult to determine the significance of these variations due to a lack of standardisation in the time between assessments, the method of measurement, and the definition of fluctuation itself.10 13 Nonetheless, many important findings have been made, as discussed below.

LONG-TERM IOP FLUCTUATION The definition of long-term IOP fluctuation varies across studies. One definition refers to the difference between the highest and lowest IOP values over a given period, with measurements occurring on different days.14 Alternatively, numerous studies define IOP fluctuation as the SD in IOP over a given time.1 2 11 13 15–22 To cite: Leidl MC, Choi CJ, Syed ZA, et al. Br J Ophthalmol Published Online First: [ please include Day Month Year] doi:10.1136/bjophthalmol2013-303980

Studies that argue that long-term IOP fluctuation is significant

Several studies suggest that long-term IOP fluctuation is an important prognostic indicator for glaucomatous damage. Hong et al16 reviewed 408 eyes

Leidl MC, et al. Br JArticle Ophthalmolauthor 2014;0:1–5. Copyright (ordoi:10.1136/bjophthalmol-2013-303980 their employer) 2014. Produced

with either primary open-angle glaucoma (POAG) or chronic primary angle-closure glaucoma (PACG), all of which had an IOP less than 18 mm Hg following phacoemulsification, posterior chamber intraocular lens implantation, and trabeculectomy. Over at least 3 years of follow-up, the authors found that, of patients with a SD in IOP greater than 2 mm Hg, 30% of those with POAG and 28.6% of those with chronic PACG demonstrated VF loss, compared to 9.7% and 10%, respectively, of those patients with SD in IOP not exceeding 2 mm Hg. Notably, the mean IOP between the two groups of patients was not significantly different, suggesting that long-term IOP fluctuation is associated with VF loss rather than the absolute value at any given time. Hong et al15 later studied 688 eyes in patients with POAG or chronic PACG who had undergone phacoemulsification after trabeculectomy. They found that after 3 years of follow-up, patients with POAG and an IOP SD greater than 2 mm Hg after surgery had a markedly worse mean VF deviation than did patients with an IOP SD of no more than 2 mm Hg. Fukuchi et al22 similarly found that patients with normal tension glaucoma (NTG) designated as fast progressors based on VF had a higher SD and range in follow-up IOP compared to slow progressors, They found no such correlation for patients with open-angle glaucoma (OAG). A cohort from the Advanced Glaucoma Intervention Study included 509 eyes with refractory OAG not well controlled with medication.11 The authors found that for each 1 mm Hg increase in IOP fluctuation (SD in IOP), the odds of VF progression increased by about 30%. Eyes with IOP fluctuation of 3 mm Hg or more demonstrated greater VF deterioration than those with fluctuation less than 3 mm Hg. Rao et al20 report similar results in a large, retrospective analysis of patients with treated POAG or PACG. They found that of mean IOP, peak IOP and IOP fluctuation (SD in IOP over several follow-up visits), peak IOP and IOP fluctuation were significantly associated with disease progression in univariate analysis, while only IOP fluctuation remained significantly associated in multivariate analysis. They note that for each 1 mm Hg increase in IOP fluctuation, progression worsened by 0.35% per year. Lee et al17 performed a multicentre, retrospective chart review of 151 patients with POAG, ocular hypertension (OHT), NTG, or findings suspicious for glaucoma. They found that IOP SD was significantly associated with progression—each 1 mm Hg increase in SD increased the risk for glaucoma progression by a factor of 4.2 in patients with measurements before disease worsening or treatment initiation.

by BMJ Publishing Group Ltd under licence.

1

Downloaded from bjo.bmj.com on October 8, 2014 - Published by group.bmj.com

Review Studies that argue that long-term IOP fluctuation is not significant A number of studies have reported that long-term IOP fluctuation has no role in ocular disease. A randomised cohort from the Early Manifest Glaucoma Trial consisting of 129 treated and 126 control patients with glaucoma found a non-significant, positive correlation between time to progression of disease and IOP SD, while mean IOP, had a significant, negative correlation.1 Additionally, a retrospective cohort study of patients from the Glaucoma Progression Study followed 587 eyes with various subtypes of glaucoma.2 Multivariate analysis determined that peak IOP, but not SD in IOP, was associated with glaucoma progression. Medeiros et al18 found comparable results in their study of 252 eyes in 126 patients with untreated OHT. They noted a significant, positive correlation between mean IOP and SD in IOP, but that IOP fluctuation was not a significant marker for progression to glaucoma in either univariate or multivariate analysis, while mean IOP was. Fogagnolo et al19 analysed IOP fluctuation in 52 patients with treated POAG, of whom 28 progressed during the study period. Over four follow-up visits, each 6 months apart, the authors found no significant difference in either short-term or long-term IOP fluctuation between patients who progressed and those who remained stable. Lee et al21 found comparable results in patients with NTG and at least 5 years of follow-up, reporting no significant association between SD in IOP and VF progression in univariate or multivariate analysis. Bengtsson and Heijl studied a cohort of 90 patients from the Malmö Ocular Hypertension Study, which prospectively followed patients with normal VFs and an IOP of at least 22 mm Hg.23 They defined IOP variation using several parameters including: variation in measurements obtained at 0800, 1130 and 1530; the maximum range from a series of diurnal curves; and the difference between highest and lowest IOP throughout the entire study period (mean follow-up of 8.5 years). They found that IOP fluctuation defined in each of these manners was not an independent risk factor for glaucoma development in patients with high-risk OHT. Finally, Realini et al24 conducted a chart review with the primary goal of checking for asymmetry in IOP fluctuation between fellow eyes. With a minimum of 1 year of follow-up, they found that IOP fluctuation between fellow eyes did not vary significantly between healthy patients and those with glaucoma.

SHORT-TERM IOP FLUCTUATION As with long-term IOP fluctuation, there is no consensus on how to define short-term IOP fluctuation. One commonly used definition applied by Lee et al10 defines it as the difference between the highest and lowest IOP over 24 h or less, though the SD in IOP based on a curve has also been advocated.19 Most studies of repeated IOP measurements throughout the day have determined that values tend to peak early in the morning and decline over the course of the day, though the exact timing of peaks and nadirs is not entirely uniform across reports.9 12 25–37

Studies that argue that short-term IOP fluctuation is significant Numerous reports demonstrate a correlation between increased short-term IOP fluctuation and pressure-related eye diseases. David et al28 assessed 690 IOP curves made from four to six 2

measurements over the course of 10.5 h, and found that the difference in mean IOP peak and trough differed significantly between healthy eyes (5 mm Hg), eyes with OAG and chronic angle-closure glaucoma (ACG) (5.8 mm Hg), and eyes with OHT (6.8 mm Hg). A more recent study also showed that IOP fluctuation is significantly higher in eyes with primary chronic ACG (7.69±3.03 mm Hg) or POAG (8.31±2.58 mm Hg) compared to normal eyes (4.83±2.46 mm Hg).38 Similarly, Grippo et al39 followed the protocol of prior works and combined results to determine that daytime IOP variation—though not nighttime variation—was significantly greater in subjects with OHT and glaucoma than healthy individuals. Baskaran et al40 determined that the difference between the peak and trough IOP in patients with primary angle closure (PAC) and PACG was significantly greater than that in PAC suspects and controls. Further, Kim et al41 noted that during waking hours, patients with NTG had a significantly greater degree of IOP fluctuation than controls. Tajunisah et al42 reported similar results in a study of glaucoma suspects, noting that the mean magnitude in IOP variation for patients with POAG, NTG, glaucoma suspicion and OHT was significantly higher than that for controls. Saccà et al43 note that patients with POAG had a greater relative daily IOP fluctuation (7–9.6%) than patients with NTG (−4.7–6.4%) or healthy eyes (−3.4–6.9%). Twenty-three patients of a cohort of 29 with OHT were available for final analysis in a 5-year follow-up study of IOP by Thomas et al,44 which found that four patients had progressed to glaucoma. Diurnal IOP profiles of these patients with readings taken every 2 h from 10:00 to 18:00 determined that the mean IOP variation was 8.6 mm Hg in the patients who progressed, compared to 5.4 mm Hg in those who did not. One study used frequency doubling technology (FDT) perimetry to study 33 eyes with OHT while measuring IOP at 0830, 1030 and 1530.45 The authors discovered that office IOP fluctuation was significantly greater in patients with abnormal FDT perimetry results (median 5 mm Hg) compared to those with normal FDT perimetry results (median 2 mm Hg). Office IOP fluctuation was also correlated with the number of depressed points on FDT perimetry. Similarly, Sakata et al46 shows that 24 h IOP fluctuation in the habitual position in patients with NTG had a significant, negative correlation with mean VF deviation. Analysis of daytime IOP curves from 149 patients with OHT found that 33 of the eyes studied had a difference of more than 5 mm Hg between the peak and trough IOP in their diurnal curve.47 Of these, 64% had VF defects within 4 years. By contrast, of those eyes with a fluctuation in IOP not exceeding 5 mm Hg, 84% had normal VFs after at least 5 years; these differences were significant. In a prospective study, Asrani et al48 reported on 105 eyes from 64 patients with OAG who were monitored via VF and home tonometry five times daily. Patients in the highest quartile of home IOP range (at least 11.8 mm Hg) had a cumulative risk of VF progression of 88% over 8 years, compared to 57% for patients in the lowest quartile for IOP range (no more than 7.7 mm Hg). A study of 3561 IOP profiles from 720 patients performed by Jonas et al49 analysed patients with healthy eyes, ocular HTN, preperimetric glaucoma ( patients with normal VF data, but a glaucomatous-appearing optic nerve), POAG, secondary OAG and NTG. The authors found that mean IOP fluctuation was significantly greater in patients with OHT, preperimetric glaucoma, or secondary OAG as compared with healthy eyes. Interestingly, there was no significant difference in mean IOP Leidl MC, et al. Br J Ophthalmol 2014;0:1–5. doi:10.1136/bjophthalmol-2013-303980

Downloaded from bjo.bmj.com on October 8, 2014 - Published by group.bmj.com

Review fluctuation in those with perimetric POAG compared to those with preperimetric glaucoma, OHT, or normal eyes. Moreover, eyes with NTG had no significant difference in IOP fluctuation compared to healthy eyes, but a significantly lower IOP fluctuation than eyes with OHT or preperimetric glaucoma. By contrast, Jonas et al50 studied 855 eyes with NTG or POAG by monitoring IOP at 1700, 2100, 0000, 0700 and 1200. Here, 163 eyes were noted to have glaucoma progression, which were analysed to reveal that in eyes with NTG, there was a significant, negative association between glaucoma progression and IOP amplitude.

Studies that argue that short-term IOP fluctuation is not significant Several reports suggest that short-term IOP fluctuations may not be significant. Sung et al51 examined 24 h IOP and VF data over approximately 6 years in patients with newly diagnosed NTG. Univariate analysis showed no correlation between VF progression and either 24 h or follow-up IOP fluctuation, among other findings. Similarly, Lee et al36 monitored diurnal IOP in 177 patients with NTG. In univariate and multivariate analysis, the authors found no significant correlation between IOP fluctuation and either pattern standard or mean deviation on VF. Additionally, a series of 14 patients with newly diagnosed, untreated POAG, by Sehi et al52 found no significant association between diurnal changes in IOP and optic nerve head appearance. Likewise, Wang et al53 state that they found no significant association between 24 h IOP fluctuation and mean VF deviation in patients with POAG. Further, in patients with unilateral POAG, they found no difference in SD of diurnal IOP variation or IOP fluctuation between fellow eyes. As indicated above, in their analysis of patients with POAG, Jonas et al50 found no association between glaucoma progression and IOP amplitude. They also reported no significant association between IOP fluctuation and glaucoma progression in an analysis of patients with NTG and POAG as a single group. Also alluded to previously, Fogagnolo et al19 found no significant difference between patients with POAG who progressed and those who remained stable in regard to short-term IOP fluctuation. Finally, Smith measured IOP every 2 h from 0500 to 1500 and attained VFs in patients with OHT, suspected glaucoma and glaucoma.54 Analysis found mean diurnal IOP variation in 400 eyes with VF defects was not significantly different compared to 400 eyes without VF defects.

PROBLEMS WITH IOP ANALYSIS In addition to the aforementioned lack of standardised definitions for IOP fluctuation, many other problems are present in these analyses. First, there are numerous factors that may transiently influence IOP, including the Valsalva manoeuvre, eye squeezing, tear film deficiencies, astigmatism and eyelid closure.55–57 IOP has also been shown to increase as patients move from seated to supine positions,58–60 and following Humphrey VF analysis61 suggesting that physical and emotional factors may contribute to IOP elevation. Another continually referenced issue is that single IOP measurements reflect IOP only at a given instant, which could alter IOP-related calculations.13 14 28 62 63 Multiple studies report that peak IOPs tend to occur outside of normal office hours, limiting the use of office hour curves.8 36 53 54 64 In fact, Jonas et al37 reviewed 3025 diurnal IOP curves from 1072 eyes with OHT, POAG, preperimetric POAG, NTG and secondary openLeidl MC, et al. Br J Ophthalmol 2014;0:1–5. doi:10.1136/bjophthalmol-2013-303980

angle glaucoma, and found that any single IOP reading taken between 0700 and 2100 had more than a 75% chance of not being the peak IOP for that patient’s 24 h curve. While 24 h IOP monitoring may provide the most accurate measurements, it is often limited by expense and inconvenience.62 64 It is also unclear how such sampling impacts IOP, as the very process of remaining in a hospital for testing may alter an individual’s IOP curve.35 Additionally, Bagga et al65 point out that such studies assume that waking patients up in the middle of the night for measurements has no impact on IOP, which is likely an oversimplification. It has also been questioned whether or not patterns in IOP fluctuation remain stable from 1 day to the next, or between fellow eyes. Wilensky determined that 81% of controls had the same diurnal IOP pattern in each eye, compared to 58% of those with OHT and 53% of those with OAG.66 Realini et al67 68 found that healthy subjects and those with POAG show fair to good agreement in terms of individual IOP values at a given time on different days 1 week apart, but have poor agreement as regards the change in IOP between the different days. Hatanaka et al69 report that IOP in eyes with untreated OAG and OHT measured from 08:00 to 16:00 over two consecutive days showed a repeatable pattern. Early results with continuous IOP sensors suggest fair to good IOP correlation over different days and between fellow eyes in healthy, young patients,70 and repeatable nocturnal, but not daytime, IOP peaks in patients with POAG.71 Conversely, a study of patients with POAG or OHT found IOP at the same time on different days to have a range of ±14.9 to ±20.5% pretreatment and ±21.2 to ±23.1% post-treatment.72

FUTURE OF IOP ANALYSIS In light of these differing conclusions regarding IOP fluctuation, a reliable method to measure the 24 h IOP curve is paramount. Fogagnolo et al64 have used regression analysis to predict diurnal IOP based on seated and supine measurements every 3 h in three populations (healthy, young and healthy, elderly patients, and patients with POAG). Based on mathematical analysis, they determined that even by their best estimate of a 24 h IOP curve, values were incorrect in 40% of healthy, young patients, 5% of healthy, elderly patients, and 20% of those with POAG. They concluded that seated IOP alone is inadequate for providing information about peak and mean IOP, and IOP fluctuation. Bagga et al65 assert that a telemetric device must be created to measure IOP throughout the night if we are to truly understand IOP variation. There have been several animal studies on the use of surface and implantable IOP monitors, suggesting they may be safe and accurate.73–78 Authors have also begun reporting promising results in human studies of contact lens-based IOP sensors.55 70 71 76 79 80 Potential limitations of this technology that must be addressed include: user discomfort; effects on visual acuity; power supply to allow for IOP monitoring over several days or months; and a continued reliance on measurements inferred in reference to corneal properties as opposed to a true measure of ocular tension.

CONCLUSION In spite of the uncertainties and inconsistencies surrounding IOP fluctuation, short-term and long-term measurements are worth considering as potential factors in disease progression. A reliable method of continuous measurement is a sine qua non for studying the influence of IOP fluctuation on glaucoma 3

Downloaded from bjo.bmj.com on October 8, 2014 - Published by group.bmj.com

Review progression. Such a device should achieve as many of the following goals as possible: be safe and biocompatible; provide accurate, reproducible measurements over a prolonged period of time; measure IOP as frequently as possible; function independently of ocular health and/or corneal properties; be directly correlated with currently validated IOP measurement devices; and allow ambulatory measurements by the patient. Until such a tonometer is available, it is likely that a true understanding of IOP fluctuation will remain elusive.

16

17

18

19

20

Method of literature search In preparation for this review article, we conducted a comprehensive search of ophthalmology literature published between 1960 and 2013 using the following search terms: intraocular pressure; intraocular pressure fluctuation; intraocular pressure variation; diurnal intraocular pressure; significance of intraocular pressure fluctuation; diurnal intraocular pressure fluctuation importance of intraocular pressure fluctuation. Targeted searches were also performed for selected papers noted in the bibliographies of articles found with the above search terms, or which came recommended from other sources. Contributors SAM developed the idea for this review paper and oversaw its writing, editing, and submission. SAM is also the guarantor of this article. CJC and ZAS reviewed and edited the article. They also made contributions to further clarify several key points in the paper. MCL conducted the initial literature search and composed the manuscript.

21

22

23

24

25 26

27

Competing interests None. Provenance and peer review Not commissioned; externally peer reviewed.

28 29

REFERENCES 1

2

3

4

5 6 7 8 9 10 11

12

13

14

15

4

Bengtsson B, Leske MC, Hyman L, et al. Early Manifest Glaucoma Trial Group. Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial. Ophthalmology 2007;114:205–9. De Moraes CG, Juthani VJ, Liebmann JM, et al. Risk factors for visual field progression in treated glaucoma [Correction appears in Arch Ophthalmol 2011;129:878]. Arch Ophthalmol 2011;129:562–8. Heijl A, Leske MC, Bengtsson B, et al. Early Manifest Glaucoma Trial Group. Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial. Arch Ophthalmol 2002;120:1268–79. The AGIS Investigators. The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration. Am J Ophthalmol 2000;130:429–40. Greenridge KC, Spaeth GL, Traverso CE. Change in appearance of the optic disc associated with lowering of intraocular pressure. Ophthalmology 1985;92:897–903. Shin DH, Bielik M, Hong YJ, et al. Reversal of glaucomatous optic disc cupping in adult patients. Arch Ophthalmol 1989;115:1599–603. Stamper RL. A history of intraocular pressure and its measurement. Optom Vis Sci 2011;88:E16–28. Drance SM. The significance of the diurnal phasic variation of intraocular pressure in normal and glaucomatous eyes. Trans Can Opthalmolog Soc 1960;23:131–40. Kitazawa Y, Horie T. Diurnal variation of intraocular pressure in primary open-angle glaucoma. Am J Ophthalmol 1975;79:557–66. Lee PP, Sultan MB, Grunden JW, et al. Assessing the importance of IOP variables in glaucoma using a modified Delphi Process. J Glaucoma 2010;19:281–7. Nouri-Mahdavi K, Hoffman D, Coleman AL, et al. Advanced Glaucoma Intervention Study. Predictive factors for glaucomatous visual field progression in the Advanced Glaucoma Intervention Study. Ophthalmology 2004;111:1627–35. Mottet B, Chiquet C, Aptel F, et al. 24-hour intraocular pressure of young healthy humans in supine position: rhythm and reproducibility. Invest Ophthalmol Vis Sci 2012;53:8186–91. Caprioli J, Coleman AL. Intraocular pressure fluctuation a risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study. Ophthalmology 2008;115:1123–9.e3. Cronemberger S, Silva AC, Calixto N. Importance of intraocular pressure measurement at 6:00 a.m. in bed and in darkness in suspected and glaucomatous patients. Arq Bras Oftalmol 2010;73:346–9. Hong S, Kim CY, Seong GJ. Long-term intraocular pressure fluctuation and visual field progression in glaucoma patients with low intraocular pressure after post-trabeculectomy phacoemulsification. J Ocul Pharmacol Ther 2007;23:571–6.

30 31

32 33

34 35

36

37 38

39

40

41

42

43

Hong S, Seong GJ, Hong YJ. Long-term intraocular pressure fluctuation and progressive visual field deterioration in patients with glaucoma and low intraocular pressures after a triple procedure. Arch Ophthalmol 2007;125:1010–13. Lee PP, Walt JW, Rosenblatt LC, et al. Association between intraocular pressure variation and glaucoma progression: data from a United States chart review. Am J Ophthalmol 2007;144:901–7. Medeiros FA, Weinreb RN, Zangwill LM, et al. Long-term intraocular pressure fluctuations and risk of conversion from ocular hypertension to glaucoma. Ophthalmology 2008;115:934–40. Fogagnolo P, Orzalesi N, Centofanti M, et al. Short- and long-term phasing of intraocular pressure in stable and progressive glaucoma. Ophthalmologica 2013;230:87–92. Rao HL, Addepalli UK, Jonnadula GB, et al. Relationship between intraocular pressure and rate of visual field progression in treated glaucoma. J Glaucoma 2013;22:719–24. Lee J, Kong M, Kim J, et al. Comparison of visual field progression between relatively low and high intraocular pressure groups in normal tension glaucoma patients. J Glaucoma. [Published Online First: 6 June 2013]. Fukuchi T, Yoshino T, Sawada H, et al. The relationship between the mean deviation (MD) slope and follow-up intraocular pressure (IOP) in open-angle glaucoma patients. J Glaucoma 2013;22:689–97. Bengtsson B, Heijl A. Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension. Graefes Arch Clin Exp Ophthalmol 2005;243:513–18. Realini T, Barber L, Burton D. Frequency of asymmetric intraocular pressure fluctuations among patients with and without glaucoma. Ophthalmology 2002;109:1367–71. Shapiro A, Zauberman H. Diurnal changes of the intraocular pressure of patients with angle-closure glaucoma. Br J Ophthalmol 1979;63:225–7. Dinn RB, Zimmerman MB, Shuba LM, et al. Concordance of diurnal intraocular pressure between fellow eyes in primary open-angle glaucoma. Ophthalmology 2007;114:915–20. Shuba LM, Doan AP, Maley MK, et al. Diurnal fluctuation and concordance of intraocular pressure in glaucoma suspects and normal tension glaucoma patients. J Glaucoma 2007;16:307–12. David R, Zangwill L, Briscoe D, et al. Diurnal intraocular pressure variations: an analysis of 690 diurnal curves. Br J Ophthalmol 1992;76:280–3. Hamilton KE, Pye DC, Aggarwala S, et al. Diurnal variation of central corneal thickness and Goldmann applanation tonometry estimates of intraocular pressure. J Glaucoma 2007;16:29–35. Kim MS, Kim JM, Park KH, et al. Asymmetry of diurnal intraocular pressure fluctuation between right and left eyes. Acta Ophthalmol 2011;89:352–7. Kotecha A, Crabb DP, Spratt A, et al. The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis. Invest Ophthalmol Vis Sci 2009;50:4229–36. Mosaed S, Chamberlain WD, Liu JH, et al. Association of central corneal thickness and 24-hour intraocular pressure fluctuation. J Glaucoma 2008;17:85–8. Pointer JS. The diurnal variation of intraocular pressure in non-glaucomatous subjects: relevance in a clinical context. Ophthalmic Physiol Opt 1997;17:456–65. De Vivero C, O’Brien C, Lanigan L, et al. Diurnal intraocular pressure variation in low-tension glaucoma. Eye (Lond) 1994;8:521–3. Konstas AG, Mantziris DA, Stewart WC. Diurnal intraocular pressure in untreated exfoliation and primary open-angle glaucoma. Arch Ophthalmol 1997;115:182–5. Lee YR, Kook MS, Joe SG, et al. Circadian (24-hour) pattern of intraocular pressure and visual field damage in eyes with normal-tension glaucoma. Invest Ophthalmol Vis Sci 2012;53:881–7. Jonas JB, Budde W, Stroux A, et al. Single intraocular pressure measurements and diurnal intraocular pressure profiles. Am J Ophthalmol 2005;139:1136–7. Sihota R, Saxena R, Gogoi M, et al. A comparison of the circadian rhythm of intraocular pressure in primary phronic angle closure glaucoma, primary open angle glaucoma and normal eyes. Indian J Ophthalmol 2005;53:243–7. Grippo TM, Liu JH, Zebardast N, et al. Twenty-four-hour pattern of intraocular pressure in untreated patients with ocular hypertension. Invest Ophthalmol Vis Sci 2013;54:512–17. Baskaran M, Kumar RS, Govindasamy CV, et al. Diurnal intraocular pressure fluctuation and associated risk factors in eyes with angle closure. Ophthalmology 2009;116:2300–4. Kim YK, Oh WH, Park KH, et al. Circadian blood pressure and intraocular pressure patterns in normal tension glaucoma patients with undisturbed sleep. Korean J Ophthalmol 2010;24:23–8. Tajunisah I, Reddy SC, Fathilah J. Diurnal variation of intraocular pressure in suspected glaucoma patients and their outcome. Graefes Arch Clin Exp Ophthalmol 2007;245:1851–7. Saccà SC, Rolando M, Marletta A, et al. Fluctuations of intraocular pressure during the day in open-angle glaucoma, normal-tension glaucoma and normal subjects. Ophthalmologica 1998;212:115–19.

Leidl MC, et al. Br J Ophthalmol 2014;0:1–5. doi:10.1136/bjophthalmol-2013-303980

Downloaded from bjo.bmj.com on October 8, 2014 - Published by group.bmj.com

Review 44

45

46

47 48

49 50 51

52

53

54 55

56

57 58

59 60 61

Thomas R, Parikh R, George R, et al. Five-year risk of progression of ocular hypertension to primary open angle glaucoma. A population-based study. Indian J Ophthalmol 2003;51:329–33. Dayanir V, Aydin S, Okyay P. The association of office intraocular pressure fluctuation in ocular hypertension with frequency doubling technology perimetry abnormality. Int Ophthalmol 2008;28:347–53. Sakata R, Aihara M, Murata H, et al. Intraocular pressure change over a habitual 24-hour period after changing posture or drinking water and related factors in normal tension glaucoma. Invest Ophthalmol Vis Sci 2013;54:5313–20. Gonzalez I, Pablo LE, Pueyo M, et al. Assessment of diurnal tensional curve in early glaucoma damage. Int Ophthalmol 1996–1997;20:113–15. Asrani S, Zeimer R, Wilensky J, et al. Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma. J Glaucoma 2000;9:134–42. Jonas JB, Budde WM, Stroux A, et al. Circadian intraocular pressure profiles in chronic open angle glaucomas. J Ophthalmic Vis Res 2010;5:92–100. Jonas JB, Budde WM, Stroux A, et al. Diurnal intraocular pressure profiles and progression of chronic open-angle glaucoma. Eye (Lond) 2007;21:948–51. Sung KR, Lee S, Park SB, et al. Twenty-four hour ocular perfusion pressure fluctuation and risk of normal-tension glaucoma progression. Invest Ophthalmol Vis Sci 2009;50:5266–74. Sehi M, Flanagan JG, Zeng L, et al. The association between diurnal variation of optic nerve head topography and intraocular pressure and ocular perfusion pressure in untreated primary open-angle glaucoma. J Glaucoma 2011;2011:44–50. Wang NL, Friedman DS, Zhou Q, et al. A population-based assessment of 24-hour intraocular pressure among subjects with primary open-angle glaucoma: the handan eye study. Invest Ophthalmol Vis Sci 2011;52:7817–21. Smith J. Diurnal intraocular pressure. Correlation to automated perimetry. Ophthalmology 1985;92:858–61. De Smedt S, Mermoud A, Schnyder C. 24-hour intraocular pressure fluctuation monitoring using an ocular telemetry sensor: tolerability and functionality in healthy subjects. J Glaucoma 2012;21:539–44. Pekmezci M, Chang ST, Wilson BS, et al. Effect of measurement order between right and left eyes on intraocular pressure measurement. Arch Ophthalmol 2011;129:276–81. Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993;38:1–30. Liu JH, Zhang X, Kripke DF, et al. Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes. Invest Ophthalmol Vis Sci 2003;44:1586–90. Liu JHK, Kripke DF, Hoffman RE, et al. Nocturnal elevation of intraocular pressure in young adults. Invest Ophthalmol Vis Sci 1998;39:2707–12. Liu H, Fan S, Gulati V, et al. Aqueous humor dynamics during the day and night in healthy mature volunteers. Arch Ophthalmol 2011;129:269–75. Ni N, Tsai JC, Shields MB, et al. Elevation of intraocular pressure in glaucoma patients after automated visual field testing. J Glaucoma 2012;21:590–5.

Leidl MC, et al. Br J Ophthalmol 2014;0:1–5. doi:10.1136/bjophthalmol-2013-303980

62

63 64

65 66 67 68

69

70

71 72 73

74 75 76

77 78

79 80

Barkana Y, Anis S, Liebmann J, et al. Clinical utility of intraocular pressure monitoring outside of normal office hours in patients with glaucoma. Arch Ophthalmol 2006;124:793–7. Drance SM. Diurnal variation of intraocular pressure in treated glaucoma: significance in patients with chronic simple glaucoma. Arch Ophthalmol 1963;70:302–11. Fogagnolo P, Orzalesi N, Ferreras A, et al. The circadian curve of intraocular pressure: can we estimate its characteristics during office hours? Invest Ophthalmol Vis Sci 2009;50:2209–15. Bagga H, Liu JH, Weinreb RN. Intraocular pressure measurements throughout the 24 h. Curr Opin Ophthalmol 2009;20:79–83. Wilensky JT. Diurnal variations in intraocular pressure. Trans Am Ophthalmol Soc 1991;89:757–90. Realini T, Weinreb RN, Wisniewski S. Short-term repeatability of diurnal intraocular pressure patterns in glaucomatous individuals. Ophthalmology 2011;118:47–51. Realini T, Weinreb RN, Wisniewski SR. Diurnal intraocular pressure patterns are not repeatable in the short term in healthy individuals. Ophthalmology 2010;117:1700–4. Hatanaka M, Babic M, Susanna Junior R. Twenty-four-hour repeatability of diurnal intraocular pressure patterns in glaucomatous and ocular hypertensive individuals. Clinics (Sao Paulo) 2011;66:1235–6. Mottet B, Aptel F, Romanet JP, et al. 24-Hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor. JAMA Ophthalmol 2013;131:1507–16. Mansouri K, Liu JH, Weinreb RN, et al. Analysis of continuous 24-hour intraocular pressure patterns in glaucoma. Invest Ophthalmol Vis Sci 2013;53:8050–6. Rotchford AP, Uppal S, Lakshmanan A, et al. Day-to-day variability in intraocular pressure in glaucoma and ocular hypertension. Br J Ophthalmol 2012;96:967–70. Akaishi T, Ishida N, Shimazaki A, et al. Continuous monitoring of circadian variations in intraocular pressure by telemetry system throughout a 12-week treatment with timolol maleate in rabbits. J Ocul Pharmacol Ther 2005;21:436–44. McLaren JW, Brubaker RF, FitzSimon JS. Continuous measurement of intraocular pressure in rabbits by telemetry. Invest Ophthalmol Vis Sci 1996;37:966–75. Schnell CR, Debon C, Percicot CL. Measurement of intraocular pressure by telemetry in conscious, unrestrained rabbits. Invest Ophthalmol Vis Sci 1996;37:958–65. Sánchez I, Laukhin V, Moya A, et al. Prototype of a nanostructured sensing contact lens for noninvasive intraocular pressure monitoring. Invest Ophthalmol Vis Sci 2011;52:8310–15. Todani A, Behlau I, Fava MA, et al. Intraocular pressure measurement by radio wave telemetry. Invest Ophthalmol Vis Sci 2011;52:9573–80. Downs JC, Burgoyne CF, Seigfreid WP, et al. 24-hour IOP telemetry in the nonhuman primate: implant system performance and initial characterization of IOP at multiple timescales. Invest Ophthalmol Vis Sci 2011;52:7365–75. Pajic B, Pajic-Eggspuchler B, Haefliger I. Continuous IOP fluctuation recording in normal tension glaucoma patients. Curr Eye Res 2011;36:1129–38. Lorenz K, Korb C, Herzog N, et al. Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens. J Glaucoma 2013;22:311–16.

5

Downloaded from bjo.bmj.com on October 8, 2014 - Published by group.bmj.com

Intraocular pressure fluctuation and glaucoma progression: what do we know? Matthew C Leidl, Catherine J Choi, Zeba A Syed, et al. Br J Ophthalmol published online March 13, 2014

doi: 10.1136/bjophthalmol-2013-303980

Updated information and services can be found at: http://bjo.bmj.com/content/early/2014/03/13/bjophthalmol-2013-303980.full.html

These include:

References

This article cites 79 articles, 18 of which can be accessed free at: http://bjo.bmj.com/content/early/2014/03/13/bjophthalmol-2013-303980.full.html#ref-list-1

P

Intraocular pressure fluctuation and glaucoma progression: what do we know?

While mean intraocular pressure (IOP) has long been known to correlate with glaucomatous damage, the role of IOP fluctuation is less clearly defined. ...
114KB Sizes 0 Downloads 3 Views