Mini-Review

Principles of Separation: Indications and Therapeutic Targets for Plasma Exchange Mark E. Williams* and Rasheed A. Balogun†

Summary Extracorporeal “blood purification,” mainly in the form of hemodialysis has been a major portion of the clinical activity of many nephrologists for the past 5 decades. A possibly older procedure, therapeutic plasma exchange, separates and then removes plasma as a method of removing pathogenic material from the patient. In contrast to hemodialysis, therapeutic plasma exchange preferentially removes biologic substances of high molecular weight such as autoantibodies or alloantibodies, antigen-antibody complexes, and Ig paraproteins. These molecular targets may be cleared through two alternative procedures: centrifugal separation and membrane separation. This review presents operational features of each procedure, with relevance to the nephrologist. Kinetics of removal of these plasma constituents are based on the principles of separation by the apheresis technique and by features specific to each molecular target, including their production and compartmentalization in the body. Molecular targets for common renal conditions requiring therapeutic plasma exchange are also discussed in detail. Clin J Am Soc Nephrol 9: 181–190, 2014. doi: 10.2215/CJN.04680513

Introduction

Current Indications for TPE

Therapeutic plasma exchange (TPE) belongs on a list of extracorporeal therapies that nephrologists are frequently considered experts at managing. TPE is expected to be a logical therapeutic option to consider in a disease condition in which the pathogenesis is linked to a specific toxic biologic substance that has a relatively high molecular mass (.15,000 D), a slow rate of formation, and distribution in the intravascular space (Table 1) (1). In contrast to hemodialysis or hemofiltration in which many substances with lower or middle molecular weights are targeted for removal, the target with TPE is typically a single constituent of plasma (Figure 1) (2). There are two fundamentally different technological approaches to achieve plasma exchange: separation with centrifugal forces, and separation with a filter membrane-based apparatus. They operate on different physical principles, but each is capable of efficiently fractionating plasma contents from whole blood (3) and allowing for replacement with plasma or albumin. Most clinical trial evidence on safety and efficacy of TPE has subsequently come from studies using centrifugation separation technology. Nonetheless, membrane separation is assumed to have similar efficacy in most conditions (4). Operational contrasts between centrifugation and membrane filtration, the two major technologies used to achieve TPE, are outlined in Table 2. Centrifugal apheresis separates the plasma from cellular components based on density, whereas membrane apheresis is based on molecular size. For the nephrologist to apply the TPE procedure, it is necessary to understand the methods of substance removal by both procedures and the kinetics involved.

The most recent American Society for Apheresis (ASFA) guidelines, published in 2010 and updated in 2013, include a growing list of category I indications for TPE, in which therapeutic apheresis is considered a first-line therapy, either alone or in conjunction with another therapy (5,6). ASFA category I indications for kidney disease from the most recent guidelines are shown in Table 3.

www.cjasn.org Vol 9 January, 2014

*Renal Division, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts; and † Division of Nephrology, University of Virginia, Charlottesville, Virginia Correspondence: Dr. Rasheed A. Balogun, University of Virginia Health System, P.O. Box 800133, Charlottesville, VA 22908. Email: [email protected]

Principles of Centrifugal Separation

Centrifugal flow devices most commonly deliver continuous flow from the patient to the centrifuge (Figure 2A). An anticoagulant, usually citrate, is added before centrifugation, which is then followed by return of the rest of the blood components with the appropriate replacement fluid (typically albumin or plasma) so that a continuous flow extracorporeal circuit is formed (7). The functional unit is the centrifuge itself, which spins at typical speeds of 2000–2500 rpm to separate the contents of the anticoagulated blood based on the density or specific gravity of various components of blood. Nonselective plasma removal is achieved through layering of plasma near the axis of rotation, adjacent to which is a buffy coat consisting of platelets, lymphocytes, monocytes, and granulocytes in that order extending from the axis of rotation with the red blood cells forming the outermost layer (8). The efficiency of separation of the various blood components depends on the dimensions of the centrifuge and the variable speed (revolutions per minute) of the centrifuge, which creates gravitational forces, as well as the dwell time, which is the amount of time that the blood spends in the centrifuge. Copyright © 2014 by the American Society of Nephrology

181

182

Clinical Journal of the American Society of Nephrology

Table 1. Ideal target molecule characteristics for therapeutic plasma exchange

Ideal Target Molecule Characteristic Identified etiologic agent or toxic substance High molecular mass ($15,000 D) Slow rate of formation Low turnover Low volume of distribution

Principles of Membrane Separation Although they are not able to perform cytapheresis (removal of cells), membrane plasma separators more closely resemble a continuous dialysis procedure run in isolated ultrafiltration mode (Figure 2B). Plasma exchange separates and discards the plasma with its pathogenic substance(s), with concurrent fluid replacement options typically including albumin or plasma. The major factors in the device efficiency of solute removal in membrane plasma separators are plasma filtration rates and factors intrinsic to the membrane. To avoid filter clogging within the separator, the filtration fraction is limited to 30%–35% of the plasma. As a result, 3–4 times the calculated blood volume will need to be processed to achieve the desired plasma clearance (9). Membrane plasma exchange, as commonly performed, is nonselective, removing all constituents of the plasma, both pathologic and beneficial plasma components. Intrinsic membrane properties include pore size and distribution. Sieving coefficients (calculated as the ratio of solute concentrations between filtrate and blood sides of the membrane for large molecules) are at unity for proteins with a molecular mass ranging from that of albumin (67,000) to B-lipoprotein (2,400,000), and potentially up to that of cryoglobulins (900,000). Efficiency may be further affected in vivo by factors such as formed element deposition, clotting of fibers, protein adsorption, and concentration polarization, the layering of rejected protein solutes on the membrane inner surface, all further reducing filtration itself (2,3).

Molecular Targets Intensive plasma exchange is used in the treatment of diseases in which the pathogenesis is associated with

abnormal circulating pathogenic autoantibodies (10), paraproteins, non-Ig proteins, antigen-antibody complexes, alloantibodies, endogenous toxins, exogenous poisons, or unidentified toxic plasma constituents in some cases (11). The ability to achieve and maintain reduced concentrations of target molecules with frequent plasma exchange treatments has been demonstrated for a limited number of disease states. Clinical responses have more frequently been evaluated in the absence of measurement of changes in concentration of pathogenic target molecules. The primary factors governing removal of target substances in TPE include the volume of distribution, the t1/2, and the potential for rebound of the target to elevated levels in the vascular space after the procedure. Increases in plasma volume exchanged during one TPE procedure yield diminishing return, due to removal of a fixed proportion (65%–70%) of the existing substance and dilution of the plasma level by the replacement fluid used for TPE. Therefore, the per cent decrease in plasma concentration expected during a plasma exchange diminishes as higher total plasma volume is removed: exchange of the first plasma volume (approximately 3 L in a 70-kg individual with a normal hematocrit level) would remove 63%, the next single plasma volume 23%, and the third plasma volume only 9% (Figure 3) (1,2,9,12,13). In addition, if the sieving coefficient is below unity, removal becomes less efficient. Net reduction will be affected by the redistribution from extravascular to intravascular compartments, by rates of synthesis, and by volumes of distribution approaching and then exceeding the calculated plasma volume (2). The plasma t1/2 of the molecular target affects the speed with which the plasma concentration rebounds after the TPE procedure. The quick rebound in levels for a molecule with a short t1/2 would necessitate more frequent TPE. Furthermore, transfer of target molecules is ongoing between intercellular, interstitial, and intravascular spaces. These interactions between compartments, analogous to the twopool model for small solutes, are diagrammed in Figure 4. These clearances and compartmental features, which will determine the number and frequency of TPEs required, relate ultimately to characteristics of the molecular target associated with the disease. If the antibody has a long t1/2, levels in the absence of removal will persist despite cessation of endogenous production. A t1/2 of 5 days means that the fractional

Figure 1. | Effectiveness of extracorporeal therapies in relationship to the size of target substances. Molecular masses (in kilodaltons) are as indicated. Sieving coefficients (calculated as the ratio of solute concentrations between filtrate and blood sides of the membrane for large molecules) are essentially at unity for proteins with a molecular mass ranging from that of albumin to B-lipoprotein (2,400,000 D), and potentially up to that of cryoglobulins (900,000 D). At the high end, exclusion of platelets (1–2 mm) and rejection of very high molecular mass proteins (3,000,000 D) are characteristic (2). VitB12, vitamin B12.

Clin J Am Soc Nephrol 9: 181–190, January, 2014

Therapeutic Plasma Exchange, Williams and Balogun

183

Table 2. Operational contrasts between centrifuge and membrane apheresis procedures

Characteristic

Centrifuge Therapeutic Plasma Exchange

Membrane Therapeutic Plasma Exchange

Mechanism Blood flow (ml/min) Plasma extraction (%) Plasma removal (ml/min) Anticoagulation Separation Blood volume in circuit (ml) Molecular weight cutoff (D) Sterilization Fluid replacement

Centrifugal force 10–150 80 Variable Citrate Specific gravity Approximately 180 N/A g Irradiation or ethylene oxide Albumin, fresh frozen plasma

Capillary membrane filter 150 30 30 Heparin Size 125 3 million Ethylene oxide Albumin, fresh frozen plasma

N/A, not applicable.

Table 3. ASFA category I renal indications for therapeutic plasma exchange

Kidney Disease ANCA-associated rapidly progressive GN Anti-GBM disease Cryoglobulinemia FSGS Atypical hemolytic uremic syndrome Kidney transplant

Thrombotic thrombocytopenic purpura Drug-associated thrombotic microangiopathy

Indication Dialysis dependence or diffuse alveolar hemorrhage Diffuse alveolar hemorrhage or dialysis independence Symptomatic, severea Factor H antibodies

Reported RCTs 8 1 0 0 0

ABO compatible; antibody-mediated rejection Desensitization; living donor with positive cross-match ABO incompatible; desensitization; live donor

3 0

Ticlopidine

0

0 7

Data are the numbers of randomized clinical trials reported, according to the 2013 ASFA guidelines (5). AFSA, American Society for Apheresis; RCT, randomized controlled trial; GBM, glomerular basement membrane. a One randomized clinical trial with immunoadsorption apheresis

turnover of IgM will be 19% per day, so that when production is stopped, disappearance is fairly prompt. For IgG, the t1/2 of 22 days results in only 7% turnover per day, and a longer disappearance curve (13). With TPE, pathogenic IgM molecules can be effectively depleted: because IgM is large (approximately 970,000 D) and resides 90% intravascularly, clearance will be efficiently achieved by one or two plasma exchanges (11), with minimal rebound in serum level. Most autoantibody-mediated diseases, however, are related to production of IgG, a molecule roughly one-eighth the size and residing 30%–45% in the extravascular space. With such a large plasma volume, under otherwise identical circumstances, several plasma exchanges will be required to remove the Ig from the circulation and the interstitial space and to achieve meaningful clearance (9). For IgG-mediated processes, for example, six TPEs would be expected to decrease circulating IgG levels to one-fifth or one-sixth of the baseline levels.

The growing list of conditions with pathogenic autoantibodies identified by modern molecular biology range from myasthenia gravis (versus the acetylcholine receptor) and the Miller-Fisher variant of acute Guillain-Barré syndrome (antibody to the GQ1b ganglioside), to autoimmune dilated cardiomyopathy (antibodies to the B-1 adrenergic receptor) and hepatitis C–related cryoglobulinemia (rheumatoid factor, IgM antibody to IgG). The vast majority of renal indications for TPE involve Ig removal. Meaningful depletion of smaller, shorter-lived constituents such as monoclonal free light chains or even smaller and shorter-lived substances such as free light chains and complement fragments has been harder to demonstrate.

Therapeutic Targets in Disease States Although the TPE procedure is a relatively simple and mechanical one, its effectiveness among diverse conditions

184

Clinical Journal of the American Society of Nephrology

Figure 2. | Technological approaches to therapeutic plasma exchange. Comparison of centrifuge (A) and membrane-based (B) plasma separation procedures.

remains variable, even as a greater number of potential pathogenic disease mediators have been identified. Examples of pathogenic target molecules for TPE in kidney disease are listed in Table 4. Antibodies specific to heparin and platelet factor 4 are a hallmark of heparin-induced thrombocytopenia. TPE can effectively reduce heparininduced thrombocytopenia antibody titers, measured by platelet factor 4–polyvinyl sulfate ELISA or heparininduced platelet aggregation, to low or negative levels. However, ASFA recommendations are at level 2C, a weak recommendation with low to very low quality evidence, because data are limited to small numbers of case series and reports (5). The target antigen in the neurologic syndrome neuromyelitis optica (NMO) is now understood to

be the aquaporin 4 water channel (14). The serum antibody binds to the central nervous system microvessels pia, sub, and Virchow-Robin spaces. As a result, the immune system destroys myelin in the optic nerve and spinal cord. TPE reduces inflammation during attacks of neuritis. The antibody may be a distinguishing biomarker for NMO versus multiple sclerosis and other conditions. However, only 21 of 37 patients had NMO antibodies present in one series (15). In other conditions, such as idiopathic dilated cardiomyopathy, in which autoantibodies to myocardial antigens are present in most patients, heterogeneity of clinical study outcomes may relate to the autoantibody assays in use. The same variability applies to renal indications for TPE autoantibody-induced forms of GN that do not appear to

Clin J Am Soc Nephrol 9: 181–190, January, 2014

Therapeutic Plasma Exchange, Williams and Balogun

185

Figure 3. | Target molecule kinetics during therapeutic plasma exchange. (A) Theoretical relationship between an increasing plasma volume exchanged relative to the patient’s plasma volume during the TPE procedure, and the percentage decrease in the concentration of the target molecule under idealized conditions. (B) Similar figure showing removal of target molecule from the beginning (closed circles) to the end of each of three TPE procedures (open circles), now taking into account factors such as biosynthesis, catabolism, and compartmental equilibration. Adapted from Kaplan (1) and Samtleben et al. (2). TPE, therapeutic plasma exchange.

Figure 4. | Schematic diagram showing relationships between internal compartmental and external distribution of target molecules during the therapeutic plasma exchange procedure.

benefit equally from TPE (4). For example, plasma exchange is not currently indicated for primary idiopathic membranous glomerulopathy recently described in association with antibodies reactive to M-type phospholipase A2 receptors on podocyte foot processes, a chronic condition with a slow and continuous disease process. Effectiveness of the procedure may also vary with disease activity, particularly with anti-glomerular basement membrane (GBM)

disease or rapidly progressive GN. The rationale for TPE in IgA nephropathy is for the removal of circulating pathogenic IgA molecules or immune complexes; despite studies demonstrating that TPE can reduce levels of both, clinical benefit appears to be restricted to early acute disease and may not halt disease progression (5). In deposition diseases such as amyloidosis, removal of monoclonal Ig light chains (amyloid light chain amyloidosis) or

186

Clinical Journal of the American Society of Nephrology

Table 4. Examples of pathogenic target molecules for TPE in kidney disease

Kidney Disease Anti-GBM disease Thrombotic thrombocytopenic purpura Pauci-immune rapidly progressive GN Multiple myeloma Cryoglobulinemia Recurrent FSGS Atypical HUS Kidney transplantation

Target Molecule Autoantibody reactive with type IV collagen; rapid decline in anti-GBM antibodies with TPE Acquired autoantibody reactive with ADAMTS13 enzyme Autoantibodies against components of the cytoplasm of neutrophils-sequential ANCA levels have not been performed Free k and l light chains IgM anti-IgG antibody, immune complexes Circulating glomerular permeability factor, suPAR (clinical remission correlated with reduction in suPAR levels below approximately 2000 pg/ml (45) Complement regulatory components or autoantibodies; not specifically shown Alloantibodies reactive with HLA antigens; DSAs can be removed from plasma by TPE

See the text for specific characteristics of molecules. TPE, therapeutic plasma exchange; GBM, glomerular basement membrane; ADAMTS13, a disintegrin-like and metalloprotease with thrombospondin type 1 motifs-13; suPAR, soluble urokinase receptor; HUS, hemolytic uremic syndrome; DSA, donor-specific antibody. Adapted from Sanchez and Ward (4).

b2-microglobulin (dialysis-related amyloidosis) may be inadequate given the chronic nature of the underlying process of deposition. In many cases, reduction in pathogenic molecules may only result in clinical remission if the underlying process of overproduction is also reduced. Anti-GBM Antibodies Goodpasture’s syndrome is an organ-specific autoimmune disease mediated by anti-GBM antibodies (16). Anti-GBM disease remains the prototypic renal indication for TPE. The inciting factor is unknown. Almost all patients have anti-GBM antibodies detectable in their blood. Although anti-GBM titer elevations are not established as predictive factors for kidney outcomes, they correlated significantly with the severity of morphologic changes on renal biopsy in one study (17). In Goodpasture’s syndrome, anti-GBM are antibodies directed against a region of the a3 domain of type IV collagen in the kidney and lung (18–21). Anti-GBM autoantibodies have been shown to be pathogenic through passive transfer experiments. Linear deposition of antibodies against the GBM occurs, and passive transfer in a primate model induces GN (22). Immunoreactivity of circulating Goodpasture autoantibodies to several NC 1 domains of collagen IV has been reported (20), perhaps triggered by conformational changes in the quaternary structure of the noncollagenous domain. Most patients with anti-GBM disease have circulating detectable IgG antibodies, primarily IgG1. In a recent report on the target antigens in the disease, all 57 affected patients had natural anti-GBM antibodies, although there were some differences in the target antigens (23). AntiGBM antibodies detected by ELISA are typically in the 30–120 U/ml range (19). A recent single-center report of 221 patients treated over 10 years found that serum levels of anti-GBM antibodies were an independent predictor of patient death (23). ASFA categorizes anti-GBM disease as a category I indication for TPE. on low to very low quality evidence, for diffuse alveolar hemorrhage, and category IA, strong

recommendation based on high quality evidence, for dialysis independence (5). Successful treatment of anti-GBM GN couples removal of pathogenic autoantibodies from the circulation with suppression of further autoantibody production. Early implementation of plasma exchange is essential because glomerular injury becomes irreversible once the patient is dialysis dependent. Antibody titers promptly decrease with plasma exchange and immunosuppression. In a frequently cited small randomized clinical trial, anti-GBM antibodies disappeared roughly twice as fast as in the control group (24). The trial suggested a trend toward a superior outcome in the plasma exchange group; however, its small size (n=20) and somewhat higher level of kidney function at entry in the plasma exchange group make interpretation difficult. Limited data suggest a correlation between the level of anti-GBM antibody and severity of morphologic changes in the kidney (17,24). Undetectable antibody levels are the goal of TPE therapy in anti-GBM disease. TPE achieves a rapid decline in anti-GBM antibodies (4). In the largest single-center report, the combination of plasma exchange with corticosteroids and cyclophosphamide had a beneficial effect on renal and patient outcomes compared with treatment without plasma exchange (24). Anti-GBM antibody titers should be monitored regularly and apheresis should be stopped when none are detectable, typically after 10–14 treatments. Thrombotic Thrombocytopenic Purpura The “idiopathic” acquired form of thrombotic thrombocytopenic purpura (TTP) is considered to be an autoimmune condition caused by formation of inhibitory autoantibodies (usually IgG) against the ADAMTS13 (a disintegrin-like and metalloprotease with thrombospondin type 1 motifs-13) protease (25–30). ADAMTS13 is the vWf-cleaving metalloprotease that is deficient in activity either by a congenital genetic mutation or an acquired autoimmune condition in TTP (25,28,29). The low activity of this protease leads to

Clin J Am Soc Nephrol 9: 181–190, January, 2014

large vWF multimers, which allow platelet aggregation in response to intravascular shear stress and form the critical nidus of microthrombi formation in the arterioles (31). A relatively large (102 patients) randomized controlled clinical trial has shown the superiority of TPE over plasma infusion alone to treat TTP (30). The inhibitory IgG autoantibodies against the ADAMTS13 protease are the target in this case. An additional benefit of TPE performed with fresh frozen plasma, not albumin, replacement is the ability to administer large volumes of plasma containing the deficient ADAMTS-13 enzyme (30). In rare cases of TTP due to a genetic lack of ADAMTS-13 and no inhibitor, plasma alone may be sufficient for treatment. Rapidly Progressive GN TPE is currently established as an effective therapy for ANCA-positive rapidly progressive GN in patients with advanced kidney impairment (serum creatinine.5.7 mg/dl) or dialysis dependence, and in those with diffuse alveolar hemorrhage, with no benefit over immunosuppression alone for those with mild disease (5). However, all clinical trials have included both pauci-immune (ANCA-associated) and immune complex GN. There are no clinical trials reporting on only patients with idiopathic immune complex GN. A frequently cited large randomized clinical trial for immune complex nephritis due to SLE showed no benefit of addition of TPE to a standard steroid/cyclophosphamide regimen (32). ANCA has a high molecular weight, low volume of distribution, low turnover rate, and a long t1/2 and may be pathogenic in pauci-immune GN. In the MEPEX trial by the European Vasculitis Study Group, randomization to the plasma exchange treatment arm reduced risk of dialysis dependence at 1 year (33). Myeloma Cast Nephropathy Multiple myeloma and Waldenström’s macroglobulinemia are malignant plasma cell disorders characterized by the production of monoclonal Igs by clones of B lymphocytes. The overproduction of monoclonal Ig types follows in parallel the serum concentrations of Ig types: IgG in roughly 65%, IgA in 20%, and light chains themselves in 15%. Purified native human IgG has a molecular mass of 160 kD, compared with the much larger molecular mass of IgM (970 kD). High circulating free Ig light chains, either k or l, are characteristic of myeloma cast nephropathy (31). In light chain myeloma, excessive production and luminal delivery of small light chains (22 kD for k chains, 44 kD for l chains) in excess of heavy chains leads to endocytosis of filtered light chains by the proximal tubular cells, followed by intracellular catabolism. Excessive light chain filtration overwhelms this catabolic mechanism, leading to an intracellular inflammatory cascade (34). Less commonly, proliferation of lymphocytes and plasma cells produces a pentameric monoclonal IgM protein, characteristic of Waldenström’s macroglobulinemia. Eightyfive percent of IgM proteins reside in the intravascular compartment. A majority of patients may have Bence Jones light chains in the urine, but at lower levels than in myeloma, and classic cast nephropathy does not occur. Recent ASFA guidelines give a grade 2B recommendation (weak recommendation) for myeloma cast nephropathy in combination with chemotherapy, on the basis of five

Therapeutic Plasma Exchange, Williams and Balogun

187

randomized clinical trials, especially when the light chain burden is high (excretion.10 g/24 h) (5). Although light chains lack criteria for target molecules effectively removed by TPE (e.g., large molecular weight, intravascular location, low rate of turnover), TPE is the most efficient available way to rapidly remove large amounts of light chains (35). TPE, by removing circulating light chains, reduces their filtered load, potentially diminishing renal injury. Nonetheless, the clinical benefit of TPE remains controversial. A frequently cited study from 1988 concluded that TPE achieved removal of large amounts of Bence Jones proteins and, in conjunction with chemotherapy, improved kidney function and long-term survival (35). Bence Jones proteinuria significantly decreased. However, the study has been criticized by comparison of hemodialysis and peritoneal dialysis groups, with extremely high 2-month mortality in the latter. A large randomized clinical trial failed to show benefit of TPE, but kidney biopsy was not an inclusion criterion (cast nephropathy was infrequently documented) and no free light chain measurements were included (36). A recent clinical trial indicated that a 50% reduction of free light chain levels (achieved in approximately two-thirds of participants) was effective in reversing kidney failure while improving survival (37). The dependence of renal response on light chain levels was only present in patients with cast nephropathy. A recent analysis suggested that superior light chain removal could be achieved using a “high cutoff” hemodialysis membrane, not yet available in the United States (38). Hyperviscosity syndrome is a rare but severe disorder most frequently found in Waldenström’s macroglobulinemia, characterized by production of monoclonal IgM molecules. A single plasmapheresis treatment effectively reduced IgM levels by 46% and serum viscosity by 45% in one recent report, with a reversal of hyperviscosity-related retinopathy and retinal hemodynamic parameters (39). Cryoglobulinemia Cryoglobulins consist of abnormal g globulins and complement components, with a molecular mass of approximately 200 kD, with the unusual property of precipitating in serum or plasma when chilled and redissolving when warm. When analyzed immunologically, the most common form involves a polyclonal Ig, usually IgM or IgA, having rheumatoid factor activity, and is commonly due to chronic viral infections such as hepatitis C or HIV. Complications may include hyperviscosity syndrome. Pegylated IFN-a and ribavirin are now considered the standard of care for hepatitis C management, the major cause of mixed cryoglobulinemia (40). The addition of TPE allows efficient removal of cryoglobulins, and may also improve immune complex solubility by altering the antigen–antibody ratio (41). It is most appropriate for patients with active moderate to severe cryoglobulinemia, including membranoproliferative GN, neuropathy, arthralgias, or ulcerating purpuric lesions (42). Case series and reports, but no randomized trials, support the use of TPE in cryoglobulinemia, performed with warmed lines and replacement fluids to prevent precipitation (4,43). Recurrent FSGS Researchers recently identified soluble urokinase receptor in the plasma of patients with recurrent FSGS, capable

188

Clinical Journal of the American Society of Nephrology

of inducing profound albuminuria when incubated with isolated rat glomeruli (38,39). It may be causative in the proteinuria through a mechanism that includes lipid-dependent activation of the a5b3 integrin (44,45). One risk factor for recurrence is elevated permeability activity detected through an in vitro assay (44,46). The factor appears to be a small protein with one or more glycation sites, with an apparent molecular mass of approximately 50 kD (44). Galactose affinity chromatography has identified cardiotrophin-like cytokine-1 present in the circulation at up to 100 times normal in patients with recurrent FSGS, in the active fraction. Pretransplant TPE may be effective in preventing or delaying recurrence of FSGS in high-risk patients (44,47). Nonrandomized clinical trials and case series indicate that removal of the factor by TPE is associated with partial or complete remission of the nephrotic syndrome in recurrent disease (44,46,48). Hemolytic Uremic Syndrome There is no compelling evidence that TPE generally benefits patients with diarrhea-associated hemolytic uremic syndrome (HUS), although some patients in the recent European outbreak responded (49). In contrast, TPE has been first-line treatment for atypical HUS (5), although without prospective trials. A growing list of genetic mutations and polymorphisms are now known to predispose to atypical HUS, most commonly involving complement regulators or activators, including complement factor H, complement factor I, and membrane cofactor proteins (50). Recent guidelines recommend TPE for removing circulating complement regulatory components or autoantibodies, while replacing deficient factors with fresh frozen plasma, the strongest recommendation being for those with factor H autoantibodies (51). Kidney Transplantation The use of plasmapheresis in renal transplantation is generally in one of two scenarios; (1) the use as part of a pretransplantation protocol to decrease immunologic risk of renal allograft rejection (anti-HLA antibody “desensitization” or ABO blood group incompatible transplantation), consequently expanding access to renal transplantation; and (2) use as part treatment for antibody-mediated rejection after transplantation (52). ESRD patients who have high panel-reactive antibodies or donor-specific antibodies undergo desensitization, a complex medical regimen in which donor-specific antibodies are eliminated and production of new antibodies is inhibited to decrease immunologic risk and allow safer transplantation (52–58). Acute humoral rejection of renal allografts is caused by alloantibodies that cause kidney injury in the peritubular capillaries, resulting in endothelial damage, loss of capillary patency, ischemia, and proliferation of myofibroblasts. TPE is used as part of the treatment of acute humoral rejection (52). Because of the conditions treated and the operational features inherent to extracorporeal TPE, an understanding of target molecules and the kinetics of their removal by the procedure is valuable to the nephrologist. Centrifugal and membrane separation each achieve the goals of plasma exchange, through contrasting technology. Although a growing number of target molecules of pathophysiologic relevance to human diseases are being identified, quantitative methodology

has yet to be applied in most cases. In contrast to the uremic syndrome, in which multiple molecules of diverse size accumulate and require removal by dialysis, conditions typically treated by TPE involve a single dominant disease mediator. The application of concepts such as “adequacy,” familiar to the nephrologist, needs to be evaluated if clinical outcomes of TPE are to be better understood. Disclosures M.E.W. is a consultant for Sanofi Aventis and Nephrogenex. R.A.B. serves on the advisory boards for Octapharma and Alexion.

References 1. Kaplan AA: Therapeutic plasma exchange: A technical and operational review. J Clin Apher 28: 3–10, 2013 2. Samtleben W, Randerson DH, Blumenstein M, Habersetzer R, Schmidt B, Gurland HJ: Membrane plasma exchange: Principles and application techniques. J Clin Apher 2: 163–169, 1984 3. Gurland HJ, Lysaght MJ, Samtleben W, Schmidt B: A comparison of centrifugal and membrane-based apheresis formats. Int J Artif Organs 7: 35–38, 1984 4. Sanchez AP, Ward DM: Therapeutic apheresis for renal disorders. Semin Dial 25: 119–131, 2012 5. Schwartz J, Winters JL, Padmanabhan A, Balogun RA, Delaney M, Linenberger ML, Szczepiorkowski ZM, Williams ME, Wu Y, Shaz BH: Guidelines on the use of therapeutic apheresis in clinical practice-evidence-based approach from the Writing Committee of the American Society for Apheresis: The sixth special issue. J Clin Apher 28: 145–284, 2013 6. Szczepiorkowski ZM, Winters JL, Bandarenko N, Kim HC, Linenberger ML, Marques MB, Sarode R, Schwartz J, Weinstein R, Shaz BH; Apheresis Applications Committee of the American Society for Apheresis: Guidelines on the use of therapeutic apheresis in clinical practice—evidence-based approach from the Apheresis Applications Committee of the American Society for Apheresis. J Clin Apher 25: 83–177, 2010 7. McLeod BC: Therapeutic apheresis: History, clinical application, and lingering uncertainties. Transfusion 50: 1413–1426, 2010 8. Wehrli G: Therapeutic apheresis instrumentation. J Clin Apher 26: 286–290, 2011 9. Ward DM: Conventional apheresis therapies: A review. J Clin Apher 26: 230–238, 2011 10. Keller AJ, Urbaniak SJ: Intensive plasma exchange on the cell separator: Effects on serum immunoglobulins and complement components. Br J Haematol 38: 531–540, 1978 11. Okafor C, Ward DM, Mokrzycki MH, Weinstein R, Clark P, Balogun RA: Introduction and overview of therapeutic apheresis. J Clin Apher 25: 240–249, 2010 12. Derksen RH, Schuurman HJ, Meyling FH, Struyvenberg A, Kater L: The efficacy of plasma exchange in the removal of plasma components. J Lab Clin Med 104: 346–354, 1984 13. Kaplan AA: Therapeutic plasma exchange: Core curriculum 2008. Am J Kidney Dis 52: 1180–1196, 2008 14. Kim SH, Kim W, Huh SY, Lee KY, Jung IJ, Kim HJ: Clinical efficacy of plasmapheresis in patients with neuromyelitis optica spectrum disorder and effects on circulating anti-aquaporin-4 antibody levels. J Clin Neurol 9: 36–42, 2013 15. Paul F, Jarius S, Aktas O, Bluthner M, Bauer O, Appelhans H, Franciotta D, Bergamaschi R, Littleton E, Palace J, Seelig HP, Hohlfeld R, Vincent A, Zipp F: Antibody to aquaporin 4 in the diagnosis of neuromyelitis optica. PLoS Med 4: e133, 2007 16. Salant DJ: Goodpasture’s disease—new secrets revealed. N Engl J Med 363: 388–391, 2010 17. Simpson IJ, Doak PB, Williams LC, Blacklock HA, Hill RS, Teague CA, Herdson PB, Wilson CB: Plasma exchange in Goodpasture’s syndrome. Am J Nephrol 2: 301–311, 1982 18. Hudson BG, Tryggvason K, Sundaramoorthy M, Neilson EG: Alport’s syndrome, Goodpasture’s syndrome, and type IV collagen. N Engl J Med 348: 2543–2556, 2003 19. Cui Z, Zhao J, Jia XY, Zhu SN, Jin QZ, Cheng XY, Zhao MH: Antiglomerular basement membrane disease: Outcomes of different

Clin J Am Soc Nephrol 9: 181–190, January, 2014

20.

21. 22. 23. 24.

25. 26.

27.

28.

29.

30.

31. 32.

33.

34. 35. 36.

37.

therapeutic regimens in a large single-center Chinese cohort study. Medicine (Baltimore) 90: 303–311, 2011 Pedchenko V, Bondar O, Fogo AB, Vanacore R, Voziyan P, Kitching AR, Wieslander J, Kashtan C, Borza DB, Neilson EG, Wilson CB, Hudson BG: Molecular architecture of the Goodpasture autoantigen in anti-GBM nephritis. N Engl J Med 363: 343–354, 2010 Jia XY, Cui Z, Yang R, Hu SY, Zhao MH: Antibodies against linear epitopes on the Goodpasture autoantigen and kidney injury. Clin J Am Soc Nephrol 7: 926–933, 2012 Lerner RA, Glassock RJ, Dixon FJ: The role of anti-glomerular basement membrane antibody in the pathogenesis of human glomerulonephritis. J Exp Med 126: 989–1004, 1967 Cui Z, Zhao J, Jia XY, Zhu SN, Zhao MH: Clinical features and outcomes of anti-glomerular basement membrane disease in older patients. Am J Kidney Dis 57: 575–582, 2011 Johnson JP, Moore J Jr, Austin HA 3rd, Balow JE, Antonovych TT, Wilson CB: Therapy of anti-glomerular basement membrane antibody disease: Analysis of prognostic significance of clinical, pathologic and treatment factors. Medicine (Baltimore) 64: 219–227, 1985 Tsai HM, Lian EC: Antibodies to von Willebrand factor-cleaving protease in acute thrombotic thrombocytopenic purpura. N Engl J Med 339: 1585–1594, 1998 Furlan M, Robles R, Galbusera M, Remuzzi G, Kyrle PA, Brenner B, Krause M, Scharrer I, Aumann V, Mittler U, Solenthaler M, La¨mmle B: von Willebrand factor-cleaving protease in thrombotic thrombocytopenic purpura and the hemolytic-uremic syndrome. N Engl J Med 339: 1578–1584, 1998 Levy GG, Nichols WC, Lian EC, Foroud T, McClintick JN, McGee BM, Yang AY, Siemieniak DR, Stark KR, Gruppo R, Sarode R, Shurin SB, Chandrasekaran V, Stabler SP, Sabio H, Bouhassira EE, Upshaw JD Jr, Ginsburg D, Tsai HM: Mutations in a member of the ADAMTS gene family cause thrombotic thrombocytopenic purpura. Nature 413: 488–494, 2001 Jin M, Casper TC, Cataland SR, Kennedy MS, Lin S, Li YJ, Wu HM: Relationship between ADAMTS13 activity in clinical remission and the risk of TTP relapse. Br J Haematol 141: 651–658, 2008 Zheng XL, Kaufman RM, Goodnough LT, Sadler JE: Effect of plasma exchange on plasma ADAMTS13 metalloprotease activity, inhibitor level, and clinical outcome in patients with idiopathic and nonidiopathic thrombotic thrombocytopenic purpura. Blood 103: 4043–4049, 2004 Rock GA, Shumak KH, Buskard NA, Blanchette VS, Kelton JG, Nair RC, Spasoff RA; Canadian Apheresis Study Group: Comparison of plasma exchange with plasma infusion in the treatment of thrombotic thrombocytopenic purpura. N Engl J Med 325: 393–397, 1991 Moschowitz E: An acute febrile pleiochromic anemia with hyaline thrombosis of the terminal arterioles and capillaries. Arch Intern Med 36: 89–93, 1925 Lewis EJ, Hunsicker LG, Lan SP, Rohde RD, Lachin JM; The Lupus Nephritis Collaborative Study Group: A controlled trial of plasmapheresis therapy in severe lupus nephritis. N Engl J Med 326: 1373–1379, 1992 Jayne DR, Gaskin G, Rasmussen N, Abramowicz D, Ferrario F, Guillevin L, Mirapeix E, Savage CO, Sinico RA, Stegeman CA, Westman KW, van der Woude FJ, de Lind van Wijngaarden RA, Pusey CD; European Vasculitis Study Group: Randomized trial of plasma exchange or high-dosage methylprednisolone as adjunctive therapy for severe renal vasculitis. J Am Soc Nephrol 18: 2180–2188, 2007 Gupta D, Bachegowda L, Phadke G, Boren S, Johnson D, Misra M: Role of plasmapheresis in the management of myeloma kidney: A systematic review. Hemodial Int 14: 355–363, 2010 Zucchelli P, Pasquali S, Cagnoli L, Ferrari G: Controlled plasma exchange trial in acute renal failure due to multiple myeloma. Kidney Int 33: 1175–1180, 1988 Clark WF, Stewart AK, Rock GA, Sternbach M, Sutton DM, Barrett BJ, Heidenheim AP, Garg AX, Churchill DN; Canadian Apheresis Group: Plasma exchange when myeloma presents as acute renal failure: A randomized, controlled trial. Ann Intern Med 143: 777–784, 2005 Leung N, Gertz MA, Zeldenrust SR, Rajkumar SV, Dispenzieri A, Fervenza FC, Kumar S, Lacy MQ, Lust JA, Greipp PR, Witzig TE,

Therapeutic Plasma Exchange, Williams and Balogun

38.

39.

40. 41. 42. 43. 44. 45.

46.

47.

48.

49. 50.

51. 52. 53.

54.

55. 56.

189

Hayman SR, Russell SJ, Kyle RA, Winters JL: Improvement of cast nephropathy with plasma exchange depends on the diagnosis and on reduction of serum free light chains. Kidney Int 73: 1282– 1288, 2008 Hutchison CA, Cockwell P, Reid S, Chandler K, Mead GP, Harrison J, Hattersley J, Evans ND, Chappell MJ, Cook M, Goehl H, Storr M, Bradwell AR: Efficient removal of immunoglobulin free light chains by hemodialysis for multiple myeloma: In vitro and in vivo studies. J Am Soc Nephrol 18: 886–895, 2007 Menke MN, Feke GT, McMeel JW, Treon SP: Effect of plasmapheresis on hyperviscosity-related retinopathy and retinal hemodynamics in patients with Waldenstrom’s macroglobulinemia. Invest Ophthalmol Vis Sci 49: 1157–1160, 2008 Lauletta G, Russi S, Conteduca V, Sansonno L: Hepatitis C virus infection and mixed cryoglobulinemia. Clin Dev Immunol 2012: 502156, 2012 Latt N, Alachkar N, Gurakar A: Hepatitis C virus and its renal manifestations: A review and update. Gastroenterol Hepatol (N Y) 8: 434–445, 2012 Iannuzzella F, Vaglio A, Garini G: Management of hepatitis C virus-related mixed cryoglobulinemia. Am J Med 123: 400–408, 2010 Berkman EM, Orlin JB: Use of plasmapheresis and partial plasma exchange in the management of patients with cryoglobulinemia. Transfusion 20: 171–178, 1980 McCarthy ET, Sharma M, Savin VJ: Circulating permeability factors in idiopathic nephrotic syndrome and focal segmental glomerulosclerosis. Clin J Am Soc Nephrol 5: 2115–2121, 2010 Wei C, Mo¨ller CC, Altintas MM, Li J, Schwarz K, Zacchigna S, Xie L, Henger A, Schmid H, Rastaldi MP, Cowan P, Kretzler M, Parrilla R, Bendayan M, Gupta V, Nikolic B, Kalluri R, Carmeliet P, Mundel P, Reiser J: Modification of kidney barrier function by the urokinase receptor. Nat Med 14: 55–63, 2008 Artero ML, Sharma R, Savin VJ, Vincenti F: Plasmapheresis reduces proteinuria and serum capacity to injure glomeruli in patients with recurrent focal glomerulosclerosis. Am J Kidney Dis 23: 574–581, 1994 Gohh RY, Yango AF, Morrissey PE, Monaco AP, Gautam A, Sharma M, McCarthy ET, Savin VJ: Preemptive plasmapheresis and recurrence of FSGS in high-risk renal transplant recipients. Am J Transplant 5: 2907–2912, 2005 Dantal J, Bigot E, Bogers W, Testa A, Kriaa F, Jacques Y, Hurault de Ligny B, Niaudet P, Charpentier B, Soulillou JP: Effect of plasma protein adsorption on protein excretion in kidney-transplant recipients with recurrent nephrotic syndrome. N Engl J Med 330: 7–14, 1994 Trachtman H, Austin C, Lewinski M, Stahl RA: Renal and neurological involvement in typical Shiga toxin-associated HUS. Nat Rev Nephrol 8: 658–669, 2012 Loirat C, Sonsino E, Hinglais N, Jais JP, Landais P, Fermanian J; The French Society of Paediatric Nephrology: Treatment of the childhood haemolytic uraemic syndrome with plasma. A multicentre randomized controlled trial. Pediatr Nephrol 2: 279–285, 1988 de Co´rdoba SR, de Jorge EG: Translational mini-review series on complement factor H: Genetics and disease associations of human complement factor H. Clin Exp Immunol 151: 1–13, 2008 Sanoff SL, Balogun RA, Lobo PL: The role of therapeutic apheresis in high immunologic risk renal transplantation: A review of current trends. Semin Dial 25: 193–200, 2012 Higgins RM, Bevan DJ, Carey BS, Lea CK, Fallon M, Bu¨hler R, Vaughan RW, O’Donnell PJ, Snowden SA, Bewick M, Hendry BM: Prevention of hyperacute rejection by removal of antibodies to HLA immediately before renal transplantation. Lancet 348: 1208–1211, 1996 Stegall MD, Gloor J, Winters JL, Moore SB, Degoey S: A comparison of plasmapheresis versus high-dose IVIG desensitization in renal allograft recipients with high levels of donor specific alloantibody. Am J Transplant 6: 346–351, 2006 Winters JL, Gloor JM, Pineda AA, Stegall MD, Moore SB: Plasma exchange conditioning for ABO-incompatible renal transplantation. J Clin Apher 19: 79–85, 2004 Haririan A, Nogueira J, Kukuruga D, Schweitzer E, Hess J, Gurk-Turner C, Jacobs S, Drachenberg C, Bartlett S, Cooper M: Positive

190

Clinical Journal of the American Society of Nephrology

cross-match living donor kidney transplantation: Longer-term outcomes. Am J Transplant 9: 536–542, 2009 57. Tyde´n G, Donauer J, Wadstro¨m J, Kumlien G, Wilpert J, Nilsson T, Genberg H, Pisarski P, Tufveson G: Implementation of a protocol for ABO-incompatible kidney transplantation—a three-center experience with 60 consecutive transplantations. Transplantation 83: 1153–1155, 2007

58. Tyde´n G, Kumlien G, Genberg H, Sandberg J, Lundgren T, Fehrman I: ABO incompatible kidney transplantations without splenectomy, using antigen-specific immunoadsorption and rituximab. Am J Transplant 5: 145–148, 2005 Published online ahead of print. Publication date available at www. cjasn.org.

Principles of separation: indications and therapeutic targets for plasma exchange.

Extracorporeal "blood purification," mainly in the form of hemodialysis has been a major portion of the clinical activity of many nephrologists for th...
869KB Sizes 0 Downloads 0 Views