+Model

ARTICLE IN PRESS

DIII-396; No. of Pages 10

Diagnostic and Interventional Imaging (2014) xxx, xxx—xxx

REVIEW / Thoracic imaging

Thoracic dual energy CT: Acquisition protocols, current applications and future developments M. Ohana ∗, M.Y. Jeung , A. Labani , S. El Ghannudi , C. Roy Department of Radiology, Nouvel Hôpital Civil, University Hospitals of Strasbourg, 1, place de l’Hôpital, 67000 Strasbourg, France

KEYWORDS Computed tomography; Dual-energy; Chest; Pulmonary embolism; CT Angiography

Abstract Thanks to a simultaneous acquisition at high and low kilovoltage, dual energy computed tomography (DECT) can achieve material-based decomposition (iodine, water, calcium, etc.) and reconstruct images at different energy levels (40 to 140 keV). Post-processing uses this potential to maximise iodine detection, which elicits demonstrated added value for chest imaging in acute and chronic embolic diseases (increases the quality of the examination and identifies perfusion defects), follow-up of aortic endografts and detection of contrast uptake in oncology. In CT angiography, these unique features are taken advantage of to reduce the iodine load by more than half. This review article aims to set out the physical basis for the technology, the acquisition and post-processing protocols used, its proven advantages in chest pathologies, and to present future developments. © 2014 Éditions franc ¸aises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

Dual energy computed tomography (DECT) is a recently commercially available technology that is used in a growing number of healthcare institutions, mainly university hospitals, offering numerous benefits in chest imaging [1,2]. This review article aims to set out the physical basis for the technology, familiarise the reader with the acquisition and post-processing protocols used, list its proven advantages in chest pathologies and to present current and future developments.



Corresponding author. E-mail address: [email protected] (M. Ohana).

2211-5684/$ — see front matter © 2014 Éditions franc ¸aises de radiologie. Published by Elsevier Masson SAS. All rights reserved. http://dx.doi.org/10.1016/j.diii.2014.01.001

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

2

M. Ohana et al.

Basic principles of dual energy computed tomography Physical basis DECT is based on the simultaneous acquisition at low and high kilovoltage, usually 80 kV and 140 kV [3]. This principle, which has already been applied in conventional radiology, was transposed to computed tomography only recently. In commercially available scanners [4], this virtually simultaneous volume acquisition at two different energies is made possible through the use of two different approaches (Fig. 1): • dual source DECT (Somatom Definition FLASH, Siemens), which uses two pairs of X-ray tubes/detectors systems positioned approximately 95◦ apart that rotate around the patient simultaneously. The advantage of this technique is that it is possible to calibrate the current (mA) separately for high and low energy, to optimise the dose delivered. The main drawback is that the field of view is limited to a diameter of 33 cm; • single source DECT (Discovery CT 750 HD, GE Healthcare), which uses a single X-ray tube/detector system that alternates very quickly between high and low kV every 0.5 msec (‘‘fast kV-switching’’) thanks to detectors with very short afterglow. The main advantages are a full field of acquisition and the potential to directly quantify material, at the expense of delivering a higher radiation dose. All of the illustrations in this article have been taken from a single source DECT scanner. The main advantage of DECT is that the simultaneous acquisition means that material decomposition can be exploited [5]. The higher the molecular weight of a material, the greater the absorption differences between high and low kilovoltage are, due to the increased likelihood of a photoelectric effect at a lower kV (Fig. 2). This is particularly marked for iodine. A post-processing system uses these differential data to generate [6]: • material density images, obtained through the material decomposition technique of dual energy acquisitions using two specific absorption spectra. The chosen pair is usually water and iodine, allowing the calculation of

Figure 2. Attenuation spectrum of different materials at different X-ray energies. At a low kilovoltage, materials with a high molecular weight (mainly iodine) show greater X-ray absorption due to a greater likelihood of the photoelectric effect occurring.

iodine-density images that create a contrast uptake map, and water-density images that remove iodine to produce a virtual non-contrast image (Fig. 3); • monochromatic images, which are real-time image reconstructions at a given energy level, every single keV within the range of 40 to 140 keV. The main advantage is the potential to dynamically reduce keV, which increases the contrast of iodine (Fig. 4), at the expense of the signal-to-noise ratio.

Acquisition protocols There is no external difference between a single and a dual energy examination: positioning of the patient, programming the acquisition, and setting it running differ only slightly from a usual protocol. Specifically, there is no increase in time taken to position the patient or carry out the acquisition. For a chest examination, we recommend an injection of 50 to 80 mL of a 350 mg/mL iodine contrast media. In CT pulmonary angiography (CTPA), an automatic power injector will be used with a flow rate at 3.5 mL/sec, a 50 mL saline chaser and a bolus tracking technique, with a region of interest (ROI) in the pulmonary artery and a threshold of 60 HU [7].

Figure 1. Currently available dual energy CT systems: dual source with two separate pairs of X-ray tubes/detectors positioned at 95◦ (a), and single source with ultrafast switching between high and low kV using a single pair of X-ray tube/detectors (b).

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

Dual energy CT in chest pathology

3

Figure 3. Material-density images. Starting with images acquired using dual energy (a), two-material decomposition using water and iodine generates a set of iodine-density images (b) that act as an extraction of iodine, and a set of water-density images (c), equivalent to non-contrast acquisitions.

Figure 4. noise.

Monochromatic reconstructions at different energy levels. Reducing keV increases the iodine contrast, at the expense of greater

Post-processing Post-processing is essential to study examinations acquired in dual energy [3,4] in a dynamic fashion. This means that a dedicated workstation or server and 5 to 10 minutes additional interpretation time are required. The learning curve is quick, entailing a rapid training session with the software. To review monochromatic images, some authors recommend analysing the data on a single reconstruction series, usually at 70 keV [2]. In our experience, more can be gained from a dynamic interpretation of these reconstructions using a wider range of energies (from 40 to 80 keV — the concept of ‘‘spectral surfing’’), giving the radiologist the opportunity to finely adjust the contrast of the image and the noise, which can sometimes become important at very low energies (< 55 keV). Iodine-density images will be used to obtain an equivalent of parenchymal perfusion: averaging the slices at a thickness of 3 mm and narrowing the window (Fig. 5) is sufficient to obtain information that is very closely correlated to the perfusion scintigraphy [8,9].

Radiation dose Dual energy acquisition delivers more radiation dose than a single energy scan carried out using the same machine [10,11]. This increase varies depending on the manufacturer and the protocol used. In chest imaging, it ranges between +5% and +40% [7,12], which may pose an obstacle for usage of this technique in younger patients. In our experience,

mean dose length product is around 340 mGy.cm, consistently below national and international standards (French diagnostic reference level for a chest CT is 475 mGy.cm). Technological advances, both those that are underway and those yet to come, will gradually minimise [11,13] and probably nullify this difference in radiation exposure. For example, the recent incorporation of iterative reconstruction into our dual energy protocols has allowed doses to be reduced by over 20%.

Current applications of DECT in chest imaging Pulmonary embolism This is the main application for DECT in chest pathologies, with numerous publications emphasising the value of the technique [6,7,12,14—17]. In the management of acute pulmonary embolism, DECT increases the quality of the examination through an improved intraluminal enhancement obtained with monochromatic reconstructions at a lower keV [18]. This means that the peripheral pulmonary arteries are easier to analyse (Fig. 6), which increases diagnostic confidence for sub-segmental pulmonary embolism. Perfusion-like imaging, obtained through iodine-density reconstructions, offers excellent correlation with scintigraphy [8,15,19] and allows perfusion defects to be visualised (Fig. 5). A defect is defined as a wedge-shaped triangular

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

4

M. Ohana et al.

Figure 5. Perfusion imaging. Starting with a dual energy acquisition (a), iodine-density images are reconstructed (b), averaged in 3 mm in thickness (c) and viewed with a narrowed window (d). It will be sufficient to obtain a perfusion-like imaging that correlates very closely to scintigraphy.

hypodensity, usually with a subpleural base, with normal or subnormal underlying lung parenchyma [12,20]. A close reading of iodine-density images in multiplanar reconstructions is necessary to exclude other defects which are unrelated to pulmonary embolism, such as artifacts (especially beam-hardening artifacts caused by a bolus of contrast agent within the superior vena cava), pulmonary sequestrations (due to vascularisation of aortic origin), and parenchymal diseases such as emphysema or cysts [20]. This type of perfusion imaging clearly sensitizes the examination by improving embolism detection and making it easier to find non-obstructive thrombi. Two studies come to this conclusion, with 100% sensitivity and specificity for the diagnosis of pulmonary embolism when classical CTPA images are combined with iodine-density images [9,21]. The latter may even have a role in prognosis, since a blockage in overall perfusion in excess of 30% is correlated with a poor clinical outcome [22].

These benefits are particularly useful in the investigation of pulmonary hypertension for identification of perfusion defects and markedly increase the reader’s sensitivity for the detection of arterial blockages, which aids in the diagnosis of chronic thromboembolic pulmonary hypertension (Figs. 7 and 8). By contrast, a normal iodine map can exclude this diagnosis with high specificity (Fig. 9) [9].

Aortic imaging DECT can eliminate the need of a non-enhanced phase: virtual non-contrast reconstructions (water-density images) are indeed useful for the detection of intramural hematoma or for the monitoring of aortic endografts (Fig. 10). Iodine-density images and monochromatic reconstructions at low keV, by enhancing iodine contrast, improve the detection of aortic endoleaks [23,24].

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

Dual energy CT in chest pathology

5

Figure 6. Utility of monochromatic reconstructions at low keV in CTPA: at 70 keV (a), it is impossible to make any comment on enhancement of the subpleural arterioles. At 60 (b), 50 (c), and best of all 40 keV (d), this enhancement becomes clear, ruling out a very peripheral pulmonary embolism.

Thoracic oncology For the characterisation of parenchymal (solid or ground glass) [25,26], pleural or pericardial nodules, DECT offers an improved evaluation of the presence of calcifications, and most importantly offers better detection of contrast uptakes, which can prove to be subtle, which could suggest a malignant aetiology (Fig. 11). Furthermore, DECT allows discrete quantification of iodine concentration, which could offer an additional argument for some diagnoses (Fig. 12).

Finally, it improves the detection of mediastinal and hilar lymphadenopathy by increasing the contrast between the vessels and the lymph nodes on monochromatic images at low keV [27].

Renal protection Monochromatic images at low keV and iodine-density reconstructions increase iodine contrast and thus offers better visualisation via DECT. These benefits can be put to use to reduce the amount of contrast media required while

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

6

M. Ohana et al.

Figure 7. Thirty-six year old female; investigation of pulmonary hypertension. Multiple perfusion defects (a and b: iodine-density images) corresponding to arterial obstructions (c: correlation with volume rendering).

Figure 8. Fifty-seven year old male; investigation of pulmonary hypertension. Linear endoluminal image (‘‘web’’) in the right lower lobe artery (a). Iodine-density images highlighting a perfusion defect in this area (b), confirming the pathological nature of the abnormality and leading to a diagnosis of post-embolic pulmonary hypertension.

Figure 9. Forty-six year old female; history of pulmonary embolism — post-embolic pulmonary hypertension is suspected. Perfusion images are normal (a) meaning that an embolic cause can be excluded with excellent sensitivity. Note the band of pseudo-triangular artifacts next to the bolus in the superior vena cava (b and c).

achieving an equivalent arterial enhancement [16,28]. In CTPA, an optimised DECT protocol with only 9.6 g of iodine can be used [29]; in aortic CT angiography, as only 13.6 g of iodine is required for an excellent image quality, comparable to a standard examination [30]. These protocols with drastically reduced iodine load (Fig. 13) are particularly useful in patients with moderate to severe renal failure.

Monochromatic images at high keV are also particularly useful for reducing metal artifacts and optimising the analysis of the edges of internal fixation implants. This may be valuable when a loose pedicle screw is suspected.

Bone imaging

Cardiac imaging

It is possible to detect bone marrow oedema on computed tomography by using water-density images that eliminate calcium [31]. This could be useful for determining whether a spinal compression fracture is recent or consolidated (Fig. 14).

Cardiac DECT with ECG gating has only recently been made been commercially available. It may prove useful in the CT study of myocardial perfusion, both at rest and under pharmacological stress, by offering improved image quality with better analysis of myocardial enhancement and a

Developments

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

Dual energy CT in chest pathology

7

Figure 10. Sixty-one year old male; follow-up imaging after TEVAR (a). Rounded hyperdensity within the aneurysmal sac (b). Iodine-density (c) and virtual non-contrast images (d) confirm that it is indeed contrast media: type II endoleak.

Figure 11. Fifty-seven year old female; investigation of chronic obstructive pulmonary disease (COPD). Nodule in the left upper lobe measuring 7 mm with slightly irregular borders (a). On iodine-density images, contrast uptake indicates that it is tissular (b). A follow-up study four months later demonstrated a volume growth of around 25%, confirming its suspicious nature.

reduction of beam-hardening artifacts [32—37]. It may also allow direct quantification of myocardial concentration of iodine and various index calculations. In late myocardial enhancement imaging, DECT could increase the sensitivity of lesion detection through iodinedensity reconstructions [38,39]. This might be possible even without the use of ECG gating.

Ventilation imaging Ventilation imaging with DECT uses noble gases with high atomic numbers, such as xenon [40,41] or krypton [42], which distribute in a similar way to air and have a good clinical safety profile. They are thus able to play the role of a ‘‘gaseous contrast’’ and they are detectable and

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

8

M. Ohana et al.

Figure 12. Fifty-one year old female; investigation of a nodule of the left lung base with regular borders (a). On iodine-density images (b): intense iodine concentration similar to that of the aorta (nodule = 5 mg.cm−3 and aorta = 5.5 mg.cm−3 ). This means that it is a vascular structure: distal pulmonary artery aneurysm, also clearly visible on volume rendered reconstructions (c).

quantifiable on DECT through material-specific images, thus producing a true ventilation map. The value of this technique in comparison with ventilation scintigraphy or hyperpolarised helium MRI lies in its potential for a morphological evaluation of ventilation with a high spatial resolution, the possibility of discrete

quantification, its availability and the use of a less expensive contrast product. Clinical applications currently in development include the prediction of residual pulmonary function after segmentectomy/lobectomy, the detection of bronchiolar disease in asthmatic patients or lung transplant recipients and

Figure 13. Protocols using a very low dose of contrast media. In CTPA, 40 mL of a 240 mg/mL contrast product offers excellent image quality (a and b). For aortic CT angiography, 50 mL of a 270 mg/mL product produces an image of identical quality to that of a full dose protocol (c and d).

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

Dual energy CT in chest pathology

Figure 14. Seventy-eight year old male; compression fracture of L1 superior endplate. Water-density images removing calcium show increased density of the posterior vertebral body that corresponds to bone oedema, pointing to a recent compression fracture.

ventilation mapping in chronic obstructive pulmonary disease patients [43].

Conclusion DECT in chest imaging is rapidly moving forward, with already multiple well-supported applications, numerous avenues of research open and important advances yet to come. At present it has multiple well-supported applications. In our daily practice, we mainly make use of two of these applications: the increase in effective diagnosis in cases of acute or chronic pulmonary embolism and the drastic reduction of iodine load during CT angiography for patients with moderate to severe renal impairment. At present, the main limitation of this technique, apart from a moderate increase in interpretation time due to post-processing, is an increase in radiation exposure ranging from 5 to 40%, even though the final dose still remains well below the recommended threshold. Continuing technological improvements are already leading to reductions in this excess radiation exposure, and should therefore contribute to a much more widespread usage of this technique.

Disclosure of interest The authors declare that they have no conflicts of interest concerning this article.

References [1] Boroto K, Remy-Jardin M, Flohr T, Faivre JB, Pansini V, Tacelli N, et al. Thoracic applications of dual-source CT technology. Eur J Radiol 2008;68(3):375—84. [2] Kang MJ, Park CM, Lee CH, Goo JM, Lee HJ. Dual-energy CT: clinical applications in various pulmonary diseases. Radiographics 2010;30(3):685—98. [3] Kaza RK, Platt JF, Cohan RH, Caoili EM, Al-Hawary MM, Wasnik A. Dual-energy CT with single- and dual-source scanners: current applications in evaluating the genitourinary tract. Radiographics 2012;32(2):353—69.

9 [4] Coursey CA, Nelson RC, Boll DT, Paulson EK, Ho LM, Neville AM, et al. Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics 2010;30(4):1037—55. [5] Van Abbema JK, Van der Schaaf A, Kristanto W, Groen JM, Greuter MJW. Feasibility and accuracy of tissue characterization with dual source computed tomography. Physica Medica 2012;28(1):25—32. [6] Ferda J, Ferdová E, Mírka H, Baxa J, Bednáˇrová A, Flohr T, et al. Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution. Eur J Radiol 2011;77(2):287—93. [7] Geyer LL, Scherr M, Körner M, Wirth S, Deak P, Reiser MF, et al. Imaging of acute pulmonary embolism using a dual energy CT system with rapid kVp switching: initial results. Eur J Radiol 2012;81(12):3711—8. [8] Thieme SF, Becker CR, Hacker M, Nikolaou K, Reiser MF, Johnson TRC. Dual energy CT for the assessment of lung perfusion—– Correlation to scintigraphy. Eur J Radiol 2008;68(3):369—74. [9] Thieme SF, Graute V, Nikolaou K, Maxien D, Reiser MF, Hacker M, et al. Dual energy CT lung perfusion imaging—–Correlation with SPECT/CT. Eur J Radiol 2012;81(2):360—5. [10] Ho LM, Yoshizumi TT, Hurwitz LM, Nelson RC, Marin D, Toncheva G, et al. Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols. Acad Radiol 2009;16(11):1400—7. [11] de Broucker T, Pontana F, Santangelo T, Faivre JB, Tacelli N, Delannoy-Deken V, et al. Single- and dual-source chest CT protocols: levels of radiation dose in routine clinical practice. Diagn Interv Imaging 2012;93(11):852—8. [12] P Pontana F, Faivre JB, Remy-Jardin M, Flohr T, Schmidt B, Tacelli N, et al. L lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol 2008;15(12):1494—504. [13] Gervaise A, Teixeira P, Villani N, Lecocq S, Louis M, Blum A. CT dose optimisation and reduction in osteoarticular disease. Diagn Interv Imaging 2013;94(4):371—88. [14] Hoey ETD, Gopalan D, Ganesh V, Agrawal SKB, Qureshi N, Tasker AD, et al. Dual-energy CT pulmonary angiography: a novel technique for assessing acute and chronic pulmonary thromboembolism. Clin Radiol 2009;64(4):414—9. [15] Thieme SF, Johnson TR, Reiser MF, Nikolaou K. Dual-energy lung perfusion computed tomography: a novel pulmonary functional imaging method. Semin Ultrasound CT MR 2010;31(4):301—8. [16] Godoy MCB, Heller SL, Naidich DP, Assadourian B, Leidecker C, Schmidt B, et al. Dual-energy MDCT: comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies. Eur J Radiol 2011;79(2):e11—7. [17] Renard B, Remy-Jardin M, Santangelo T, Faivre JB, Tacelli N, Remy J, et al. Dual-energy CT angiography of chronic thromboembolic disease: can it help recognize links between the severity of pulmonary arterial obstruction and perfusion defects? Eur J Radiol 2011;79(3):467—72. [18] Viteri-Ramírez G, García-Lallana A, Simón-Yarza I, Broncano J, Ferreira M, Pueyo JC, et al. Low radiation and low-contrast dose pulmonary CT angiography: comparison of 80 kVp/60 mL and 100 kVp/80 mL protocols. Clin Radiol 2012;67(9):833—9. [19] Yang GF, Yang X, Zhang LJ, Zhu H, Chai X, Hu XB, et al. Pulmonary enhancement imaging with dual energy CT for the detection of pulmonary embolism in a rabbit model: comparison to perfusion planar scintigraphy, SPECT and SPECT-CT modalities. Acad Radiol 2011;18(5):605—14. [20] Kim BH, Seo JB, Chae EJ, Lee HJ, Hwang HJ, Lim C. Analysis of perfusion defects by causes other than acute pulmonary thromboembolism on contrast-enhanced dual-energy CT in consecutive 537 patients. Eur J Radiol 2012;81(4):e647—52.

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

+Model DIII-396; No. of Pages 10

ARTICLE IN PRESS

10 [21] Fink C, Johnson TR, Michaely HJ, Morhard D, Becker C, Reiser M, et al. Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results. Fortschr Röntgenstr 2008;180(10):879—83. [22] Apfaltrer P, Bachmann V, Meyer M, Henzler T, Barraza JM, Gruettner J, et al. Prognostic value of perfusion defect volume at dual energy CTA in patients with pulmonary embolism: correlation with CTA obstruction scores, CT parameters of right ventricular dysfunction and adverse clinical outcome. Eur J Radiol 2012;81(11):3592—7. [23] Laks S, Macari M, Chandarana H. Dual-energy computed tomography imaging of the aorta after endovascular repair of abdominal aortic aneurysm. Semin Ultrasound CT MR 2010;31(4):292—300. [24] Stolzmann P, Frauenfelder T, Pfammatter T, Peter N, Scheffel H, Lachat M, et al. Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT1. Radiology 2008;249(2):682—91. [25] Chae EJ, Song JW, Seo JB, Krauss B, Jang YM, Song KS. Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: initial experience. Radiology 2008;249(2):671—81. [26] Knöß N, Hoffmann B, Krauss B, Heller M, Biederer J. Dual energy computed tomography of lung nodules: differentiation of iodine and calcium in artificial pulmonary nodules in vitro. Eur J Radiol 2011;80(3):e516—9. [27] Ogawa M, Hara M, Imafuji A, Ozawa Y, Arakawa T, Kobayashi S, et al. Dual-energy CT can evaluate both hilar and mediastinal lymph nodes and lesion vascularity with a single scan at 60 seconds after contrast medium injection. Acad Radiol 2012;19(8):1003—10. [28] Yuan R, Shuman WP, Earls JP, Hague CJ, Mumtaz HA, Scott-Moncrieff A, et al. Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography—–A prospective randomized trial. Radiology 2012;262(1):290—7. [29] Labani A, Ohana M, Jeung MY, Ardelean A, Hemmert C, Roy C. How far can we reduce the iodine load at CT pulmonary angiography using dual-energy: a prospective study on 40 patients. ECR 2013 [(EPOS Scientific Presentation) C-1058]. [30] Ohana M, Charton J, Jeung MY, Thaveau F, Chakfe N, Roy C. Low volume contrast media CT angiography of the aorta and the lower extremities using dual-energy CT: a prospective study on 50 patients. RSNA 2012 [(Scientific Formal Presentation) VSVA51-10(12026995)]. [31] Guggenberger R, Gnannt R, Hodler J, Krauss B, Wanner GA, Csuka E, et al. Diagnostic performance of dual-energy CT for the detection of traumatic bone marrow lesions in the ankle: comparison with MR imaging. Radiology 2012;264(1):164—73.

M. Ohana et al. [32] Weininger M, Schoepf UJ, Ramachandra A, Fink C, Rowe GW, Costello P, et al. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: initial results. Eur J Radiol 2012;81(12):3703—10. [33] Techasith T, Cury RC. Stress myocardial CT perfusion: an update and future perspective. JACC Cardiovasc Imaging 2011;4(8):905—16. [34] So A, Lee TY, Imai Y, Narayanan S, Hsieh J, Kramer J, et al. Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: preliminary experience. J Cardiovasc Comput Tomogr 2011;5(6):430—42. [35] So A, Lee TY. Quantitative myocardial CT perfusion: a pictorial review and the current state of technology development. J Cardiovasc Comput Tomogr 2011;5(6):467—81. [36] Ko BS, Cameron JD, DeFrance T, Seneviratne SK. CT stress myocardial perfusion imaging using multidetector CT—–A review. J Cardiovasc Comput Tomogr 2011;5(6): 345—56. [37] Meyer M, Nance Jr JW, Schoepf UJ, Moscariello A, Weininger M, Rowe GW, et al. Cost-effectiveness of substituting dualenergy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease. Eur J Radiol 2012;81(12):3719—25. [38] Hamilton-Craig C, Seltmann M, Ropers D, Achenbach S. Myocardial viability by dual-energy delayed enhancement computed tomography. JACC Cardiovasc Imaging 2011;4(2):207—8. [39] Bauer RW, Kerl JM, Fischer N, Burkhard T, Larson MC, Ackermann H, et al. Dual-energy CT for the assessment of chronic myocardial infarction in patients with chronic coronary artery disease: comparison with 3-T MRI. Am J Roentgenol 2010;195(3):639—46. [40] Honda N, Osada H, Watanabe W, Nakayama M, Nishimura K, Krauss B, et al. Imaging of ventilation with dual-energy CT during breath hold after single vital-capacity inspiration of stable xenon. Radiology 2012;262(1):262—8. [41] Chae EJ, Seo JB, Goo HW, Kim N, Song KS, Lee SD, et al. Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience. Radiology 2008;248(2):615—24. [42] Hachulla AL, Pontana F, Wemeau-Stervinou L, Khung S, Faivre JB, Wallaert B, et al. Krypton ventilation imaging using dualenergy CT in chronic obstructive pulmonary disease patients: initial experience. Radiology 2012;263(1):253—9. [43] Park EA, Goo JM, Park SJ, Lee HJ, Lee CH, Park CM, et al. Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique. Radiology 2010;256(3):985—97.

Please cite this article in press as: Ohana M, et al. Thoracic dual energy CT: Acquisition protocols, current applications and future developments. Diagnostic and Interventional Imaging (2014), http://dx.doi.org/10.1016/j.diii.2014.01.001

Thoracic dual energy CT: acquisition protocols, current applications and future developments.

Thanks to a simultaneous acquisition at high and low kilovoltage, dual energy computed tomography (DECT) can achieve material-based decomposition (iod...
4MB Sizes 0 Downloads 3 Views