Hindawi Publishing Corporation Journal of Analytical Methods in Chemistry Volume 2016, Article ID 9459516, 13 pages http://dx.doi.org/10.1155/2016/9459516

Research Article Virtual Instrument for Emissions Measurement of Internal Combustion Engines Armando Pérez, Rogelio Ramos, Gisela Montero, Marcos Coronado, Conrado García, and Rubén Pérez Engineering Institute, Autonomous University of Baja California, Boulevard Benito Juarez, Insurgentes Este, 21280 Mexicali, BC, Mexico Correspondence should be addressed to Rogelio Ramos; [email protected] Received 26 October 2015; Revised 27 January 2016; Accepted 28 January 2016 Academic Editor: Serban C. Moldoveanu Copyright © 2016 Armando P´erez et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The gases emissions measurement systems in internal combustion engines are strict and expensive nowadays. For this reason, a virtual instrument was developed to measure the combustion emissions from an internal combustion diesel engine, running with diesel-biodiesel mixtures. This software is called virtual instrument for emissions measurement (VIEM), and it was developed in the platform of LabVIEW 2010 virtual programming. VIEM works with sensors connected to a signal conditioning system, and a data acquisition system is used as interface for a computer in order to measure and monitor in real time the emissions of O2 , NO, CO, SO2 , and CO2 gases. This paper shows the results of the VIEM programming, the integrated circuits diagrams used for the signal conditioning of sensors, and the sensors characterization of O2 , NO, CO, SO2 , and CO2 . VIEM is a low-cost instrument and is simple and easy to use. Besides, it is scalable, making it flexible and defined by the user.

1. Introduction Air pollution is caused in large part by vehicles due to the burning of fossil fuels that emit pollutant gases such as NO, CO, SO2 , and CO2 [1, 2]. Diesel has been one of the most used fuels in internal combustion engines for more than one century [3]. It is due to its high availability, competitive prices, and high energy density. Diesel is used, for example, in urban transport, cargo transport, light-duty vehicles, agricultural machinery, ships, and electricity generation. Emissions generated by diesel combustion directly affect the health and population life quality. Likewise, these are largely responsible for the climate change problem [4–6]. The biodiesel utilization is an alternative to reduce the pollutant emissions from vehicles with internal combustion engines that run on diesel. Biodiesel is a renewable and environmental-friendly fuel that is derived from lipids. These react with a short chain alcohol in the presence of a catalyst, no matter whether it is acid, basic, or enzymatic, producing a monoalkyl esters mixture of fatty acids [7, 8]. The physicochemical characteristics of biodiesel are similar to diesel. Therefore it may be replaced partially or completely, since the

currently applied technology does not require major changes for its use. Biodiesel has become more important worldwide, and it has shown rapidly industrial growth as an alternative fuel instead of diesel [9]. Therefore, it is necessary to measure the respective emissions to determine the emissions decrease regarding the fossil fuels. International governments and organizations are currently introducing new regulations that establish more strict emission limits to reduce the greenhouse gases emissions [10– 12]. As a result, it is essential to have efficient systems that measure the emissions from internal combustion engines, as well as regulate them. (1) Current Systems for Emissions Measurement of Internal Combustion Gases. The measurement systems for emissions measurement of internal combustion usually use specialized analyzers that work under standardized methods [13]. These provide related information about the composition and quantity of the combustion gases. It is a useful tool to understand and regulate combustion. The implementation of these systems is based on taking a gas sample that is produced

2

Journal of Analytical Methods in Chemistry

Sensor SO2

Sensor O2

Sensor CO

Sensor CO2

Sensor NO

Conditioner signal from the SO2 sensor

Conditioner signal from the O 2 sensor

Conditioner signal from the CO sensor

Conditioner signal from the CO2

Conditioner signal from the NO

Signal amplifier for SO2 sensor

Signal amplifier for O2 sensor

Signal amplifier for CO sensor

Signal amplifier for CO2 sensor

Signal amplifier for NO sensor

DAQ

Information processing

Visualization PC VI

Figure 1: Operating block diagram of VIEM.

IR gas sensor

Band pass amplifiers

Active Pyro Lamp drive Ref. Pyro T

Signal conditioner

Virtual instrumentation

Temperature sensor (internal or external)

Figure 2: Blocks diagram of a typical gas detector system using an infrared sensor.

in, for example, boilers, engines, and industrial ovens. The sample passes through the electrochemical cells analyzer, obtaining the concentration of each of its components and defining its own quality. In this way, if it is carried out with the relevant current regulations is established, at the same time ensuring the equipment is in proper conditions with its resulting fuel saving.

There are several types of systems in the market for emissions measurement of internal combustion; these may also be fixed or portable depending on their implementation. Conventional systems have several disadvantages, among them we emphasize the high costs purchase from US $2.000 to $20.000, strictness, and impossibility of being scalable [14, 15]. It means that these systems may be only used

Journal of Analytical Methods in Chemistry

3

Electrochemical gas sensor (bottom view)

Set zero Set gain

as

VBi

R

Signal conditioner

S Potentiostat (bias circuit)

C

Virtual instrumentation

Transimpedance amplifier (current to voltage)

Figure 3: Block diagram of a typical gas detection system.

Capillary diffusion barrier Sensing electrode Separator Counter electrode

Counter collectors

Electrolyte Sensor pins

Figure 4: Internal sensor structure of CO2 .

for certain applications, without having the facility and flexibility to adapt them to other required uses. Currently, the systems based on the virtual instrument have been used as an alternative to the conventional systems for emissions measurement. (2) Virtual Instrument Used for the Emissions Measurement of Internal Combustion Gases. A virtual instrument is a concept that includes software and hardware systems, using a computer, that it replaces a measurement instrument and monitoring in the real world. Every piece of software and hardware that performs this function is called virtual instrument (VI). When a commercial system is used, in most of the cases the virtual instrument concept is performed in an object-oriented programming language [16]. The new scientific instrument supports the innovation and development of systems based on virtual instrument. The virtual instrument advantages are the enclosed adaptability that is included in the software and hardware and the reduction of cost for acquisition channel compared to the conventional instruments of rigid hardware of which function is determined by the manufacturer and also the easiness to be customized accordingly to the specific needs of each user and the programming language use [17]. Virtual instruments integrate nonexclusive operation hardware and powerful

software, obtaining as a consequence an instrument of a scalability architecture. This means it may be modified if it is required [18–20]. The virtual instrument implementation has been recently suggested for emissions measurement of internal combustion gases [21]. It is due that the measurement is currently performed by using stand-alone modular analyzers, used, and specialized, providing information about the gases emitted from motor combustion. Hence, virtual systems have been developed to measure and monitor the CO concentration in the gases emitted by vehicles [22]. National Instruments developed a virtual instrument for the emissions measurement generated by internal combustion engines. This instrument is based on the international emissions standards, in particular, the Euro 4 and EPA. These agencies specify the total amount of pollutants that an internal combustion engine must emit to the atmosphere. These emission factors units are defined in general as gram per mile [23]. In this work, a virtual instrument for the measurement and monitoring of emissions (VIEM), based on the LabVIEW 2010 virtual programming platform, was developed. VIEM is synchronized with the sensors, data acquisition device, and signal conditioners to measure and register in real time the emissions of O2 , NO, CO, SO2 , and CO2 . The VIEM programming, the electronic schematics diagrams used for the signal conditioning sensors, and the sensors characterization of O2 , NO, CO, SO2 , and CO2 are presented as results [24].

2. Hardware System Configuration (Hardware Details) Four main devices were involved in the system hardware configuration: firstly, the O2 , NO, CO, SO2 , and CO2 sensors, the characteristics and operating ranges for each of which are shown in Table 1; secondly, the signal conditioners and amplifiers for each sensor; thirdly, the data acquisition device (DAQ); and, lastly, the personal computer that runs the virtual instrument software, as is shown in Figure 1. The DAQ digitizes the information that signal conditioners transmit. A DAQ board USB 6009 National Instruments

Operating ranges Model Sensitivity Maximum overload Zero in air at 20∘ C Zero deviation (−20 to +40∘ C) Resolution Response time Temperature range Operating humidity Pressure range DC supply recommended

Features

SO2 0–2000 ppm EC4-2000-SO2 8–20 nA/ppm SO2 N/A < ±50 ppm SO2 0 to 4 ppm SO2 5 ppm SO2 𝑡90 < 60 s −20 to +50∘ C 15–90% RH noncondensing 90–110 kPa N/A

NO 0–250 ppm EC4-250-NO 320–480 nA/ppm NO 1000 ppm −0.06 To 4.5 ppm NO N/A 0.5 ppm NO 𝑡90 = 35 s −20 to +50∘ C 15–90% RH noncondensing 90–110 kPa N/A

Operating conditions O2 0–30% O2 EC410 N/A 100% O2 N/A N/A 0.1% O2 𝑡90 < 15 s −20 to +50∘ C 15–95% RH 90–110 kPa N/A

Table 1: Sensors characteristics and operating ranges. CO 0–500 ppm EC4-500-CO 55–85 nA/ppm CO 1500 ppm CO < ±3.1 ppm of CO N/A 1 ppm CO 𝑡90 < 30 s −20 to +50∘ C 15–90% RH noncondensing 90–110 kPa N/A

CO2 0–100% Vol. IR11BR N/A N/A N/A N/A N/A N/A −20 to +50∘ C 0–99% noncondensing 80–120 kPa. 5V

4 Journal of Analytical Methods in Chemistry

MCP6V11 VSS

0.1u

10k

R5

2

C2

+5V

VDD 1 U2

TP3

5

3+ 4−

+5V

+2V5

+5V

5

R4

10k +5V

Journal of Analytical Methods in Chemistry

C5 0.1u

GND

JP1 1 2 Power

GND GND

GND

GND

Sensor EC410 C6

TP2 R8

EC4-250-NO R10 +2V5

C

10R

C1

C3

Output 2 1

JP2 GND Con R4 = 3k9 S = 65 mV/% Vo = 2.5V − S ∗ concentration% +5V

+5V

0.1u

10R

3k9 GND TP4 VSS 4 MCP6V11 − 1 3+ U3 VDD 2

R9

S

TP1 +3V1

+2V5

4k87

R2 R3

+3V1 10k

+2V5 4k7

+2V5

IC1 LM4041C12DBZ

5

R6

+5V

2

4k7

R1

S1

0.1u GND VSS 4 MCP6V11 − 1 3 + U1 VDD

0.1u R11

5 +5V

10k C4

+5V

10k

R

R7

Bias Vout polarity −600 V Negative

C7 0.1u

0.1u

GND

GND

Figure 5: Circuit designed for O2 Conditioning signal.

model was used. Digital signals are transmitted to the laptop computer Sony Vaio, VGN-CR190 Intel Core Duo T7100 @ 1.8 GHz model, using Windows 7 operation system. 2.1. Infrared Sensor. The infrared sensor works on the basis that is known as the nondispersive infrared analyzer (NDIR), and it is used to detect the presence of carbon dioxide to a volume of 100%. It is possible to determine the CO2 concentration using an infrared source with a specific filter, in which it is installed in the optical-gas cavity. The infrared sensor is connected to an electronic signal. Signals process involves the linearization and compensation in the temperature, using algorithms in the system software [13]. 2.2. Infrared Sensor Operation. The infrared gas sensor uses a low-frequency flash lamp drive that is controlled by an excitation circuit. Infrared radiation pulses reflect inside providing a trajectory through the gas and objective. “Pyros” pyroelectric detectors are used to determine the infrared signal change. The active pyroelectric is sensitive to the changes in the infrared wavelengths that are usually absorbed by the gas, passing between the transmitter and receiver.

Figure 2 shows the block diagram of signal conditioner circuit or line amplifier. 2.3. Electrochemical Sensor Operation. Electrochemical sensors use a solid catalytic electrolyte making electrons flow of a gas cell sample to a gas cell reference possible. In practice, catalytic coated ceramic materials, for example, ZrO2 , remove the reference cell that contains a high concentration of O2 , as well as an electric sample. When the temperature increases, the electrolyte enables the oxygen ionic components transfer from the reference cell to the sample cell. The surface of the electrolyte has a special electrocatalyst layer catalyzing the transfer processing, and it works as an electrode to attract the released electrons. The ions that move from the reference side to the lateral release electrons of the sample on this surface are forced into the equilibrium. However, since the sample is replenished continuously, an ongoing electrons flow is induced through the measurement load resistance. Thereafter, the electric current is used to deduce the oxygen concentration of the electric gas sample [13], as is depicted in Figure 3. Because the electrons contain a finite catalytic activity, it is necessary to establish a limit to the diffusion speed

+5V

GND

JP1 1 2 Power

GND

GND TP3

Sensor Bias Vout polarity EC4-250-NO 300 mV Positive

+2V2

10R EC4-250-NO R10 10R

20k GND TP4 VSS 4 − 1 MCP6V11 3+ U3 VDD

+5V C3

Output 2 1

JP2 Con R4 = 20k GND S = 8 mV/ppm Vo = 2.5V + S ∗ concentration%

+2V5

+5V

2

+5V

10k

5

+2V2 R6

R9

2

S

GND VSS 4 − 1 MCP6V11 3 + U1 VDD

0.1u R11

S1

5

R8 10k C4 0.1u

+5V

R7 10k

R

TP1

C6

C

6k8

TP2

4k7

GND

C5 0.1u

+2V5 0.1u

IC1 LM4041C12DBZM R3

GND

VDD 1 U2 MCP6V11 VSS

C1 2k2

R2

+5V

+2V5

GND

R1

0.1u

10k

R5

C2

2

5

3+ 4−

+5V

R4

+2V5

+5V

Journal of Analytical Methods in Chemistry 10k +5V

6

C7 0.1u

0.1u

GND

GND

Figure 6: Circuit designed for NO signal conditioning.

of objective gas in the sensor, guaranteeing that gas reacts properly. It is performed through a barrier taking a shape of small hole or capillary located on the sensor cover, as is shown in Figure 4. 2.4. Integrated Circuits. Integrated circuits are used for conditioning and amplifying the signal that the sensors send when the amount information or gas concentration is registered. Registered voltage 𝑉𝑜 is of 2.435 V when showing 1% of oxygen; this is the minimum concentration that sensor can detect. It means that data acquisition device (DAQ) processes increments that are equivalent to 0.065 V/1% of O2 . Equation (1) was used to calculate the output voltage: 𝑉𝑜 = 2.5 V − 65 mV/% ∗ [O2 %] .

(1)

Figure 5 shows the integrated circuit diagram used for conditioning and amplifying the signal provided by the O2 sensor. Registered voltage 𝑉𝑜 is of 2.508 V when showing 1 ppm of NO; this is the minimum concentration that sensor can detect. It means that DAQ processes increments that are equivalent to 0.004 V/1 ppm of NO. Equation (2) was used to calculate the output voltage: 𝑉𝑜 = 2.5 V + 8 mV/ppm ∗ [NO ppm] .

(2)

Figure 6 shows the integrated circuit scheme used for conditioning and amplifying the signal provided by the NO sensor. Registered voltage 𝑉𝑜 is of 2.5047 V when showing 5 ppm of SO2 ; this is the minimum concentration that sensor is able to detect. It means that DAQ processes increments that are equivalent to 0.00476 V/1% of O2 . Equation (3) was used to calculate the output voltage: 𝑉𝑜 = 2.5 V + 0.952 mV/ppm ∗ [ppm SO2 ] .

(3)

Figure 7 shows the integrated circuit scheme used for conditioning and amplifying the signal provided by the SO2 sensor. Registered voltage 𝑉𝑜 is of 2.5039 V when showing 1 ppm of CO; this is the minimum concentration that sensor can detect. It means that the DAQ processes increments that are equivalent to 0.00392 V/1 ppm of CO. Equation (4) was used to calculate the output voltage: 𝑉𝑜 = 2.5 V + 3.92 mV/ppm ∗ [CO ppm] .

(4)

Figure 8 shows the integrated circuit scheme used for conditioning and amplifying the signal provided by the CO sensor. Figure 9 shows the absorbance fractional reaction regarding CO2 concentration. It allowed observing the sensitivity of the sensor that oscillates between 0 and 100% of the volume concentration of carbon dioxide.

7

C1

C4

GND

+5V

1u

C7

Power

0.1u

GND

JP1 1 2

GND

GND

GND

Sensor Bias Vout polarity EC4-2000-SO2 0 V Positive

S1

100n C

EC4-2000-SO2

R8 +2V5

10R

DD

4

− 3+

C2

VSS 1 MCP6V11 V U4

TP3

Output 2 1

DD

JP2 Con R4 = 68k GND S = 0.952 mV/ppm Vo = 2.5V + S ∗ concentration

+5V

5

10R

+5V

R3

+5V

+2V5

10k

68k GND

R7

S

2

GND VSS 4 − 1 MCP6V11 3 + V U1

100n R9

2

10k C3

5 +5V

R4

R5 R

10k

C5

D

TP1

MMBFJ177 U3 R6 G S 1M

+5V

GND

+5V

2

10k

R2

100n

TP2

5

3 + VDD 1 U2 4− MCP6V11 VSS

+5V

+2V5

R1

+5V

10k +5V

Journal of Analytical Methods in Chemistry

C6 0.1u

0.1u

GND

GND

Figure 7: Circuit designed for SO2 signal conditioning.

Figure 10 displays the integrated circuit scheme used for conditioning and amplifying the signal provided by the CO2 sensor.

3. Software Programming for Virtual Instrumentation Development This section shows the programing description of the main blocks that are part of the virtual instrument for emissions measurement that was developed in LabVIEW 2010 platform. In the figures, the operation performed by each programing block is shown. 3.1. Test Counter. The VI counts the tests that have been performed to organize the files of the experiment. It is performed through the sub-VI test counter, which it saves in a text file (.txt) with a value that starts at zero and increases to 1 for each VIEM run. The corresponding programming block is shown in Figure 11. 3.2. Configuration Window. The VI configures the set menus and toolbars using a property-node; these will be shown

during the VIEM running. In Figure 12 is observed the programming block of the configuration window. 3.3. While Loop 1. While loop 1 runs routines for the configuration and test running. The length of the test is selected using the testing time control. The sample rate configuration is performed using an acquisition time control. The subVI “direction by testing” creates the direction and file name containing the samples of test that is in running process. The function sub-VI “Write to Spreadsheet File” creates a new file for each registered variable; this will be shown using a “testing” graphic indicator. The abovementioned is found in the “Event Structure” module, which it enables to synchronize with the computer clock using a time out of 2.00 ms. While loop 1 keeps in ongoing running. In Figure 13, the programming block of while loop 1 is exposed. 3.4. While Loop 2. While loop 2 is used to receive the sensor signals. It is possible using sub-VI “acquisition.” Likewise, it configures the storage inputs directions for different variables of measurement displaying them through numerical indicators of “double” type. This series frequency depends directly on the configured value in the “acquisition time”

C1

GND

GND

+5V

VSS

C4

JP1 1 2

0.1u

Power

GND

GND

+5V

MCP6V11

+5V

2

10k

R2

100n

VDD 1 U2

TP2

5

3+ 4−

+2V5

R1

+5V

Journal of Analytical Methods in Chemistry 10k +5V

8

1u

C7 GND

GND

10k C3

S1

100n

10R R8 +2V5

EC4-500-CO

10R

4

− 3+

C2

TP3 VSS MCP6V11 1 U4 VDD

Output 2 1

JP2 GND Con R9 = 56k S = 3.92 mV/ppm Vo = 2.5V + S ∗ concentration

+5V

+5V

5

− 3 +

+5V

+2V5

R3

VSS MCP6V11 1 U1 VDD

2

4 10k

56k GND

R7

S C

GND

100n R9

2

R4

5 +5V

R5 R

10k

C5

D

TP1

MMBFJ177 U3 R6 +5V S G 1M

Sensor Bias Vout polarity EC4-500-CO 0 V Positive

C6 0.1u

0.1u

GND

GND

Figure 8: Circuit designed for CO conditioning signal.

Fractional absorbance

0.6

0.5 0.4 0.3 0.2 0.1 0.0

0

10

20 30 40 50 60 70 80 Carbon dioxide concentration (Vol%)

90

100

Figure 9: Absorbance fractional versus CO2 concentration.

control. This series has a run of “continue if true” type that is controlled using the run/stop button. Figure 14 presents the programming block of while loop 2.

3.5. Sub-VI Acquisition. Sub-VI acquisition is used for data collection of the sensors using a DAQ ASSISTANT Express VI, by which it is configured as a, nondifferential analog input to a voltage range from −10 to 10 volts. The virtual instrument “acquisition” output shows to the user the readings in a numeral indicator. Data are processed for its storage using a function sub-VI Write to Spreadsheet. It is performed for a maximum amount of 8 sensors, and data flow is monitored using the “Flats sequence” structure to avoid overload information in the acquisition time. Figure 15 reveals the sub-VI acquisition programming block. Graphical programming in LabVIEW 2010 uses the programming model for data flow in contrast to the programming based on text, basing its programming in the flow control model. Instead of typing complicated text lines, risking making syntactic and logistics mistakes, LabVIEW 2010 is based on the icons connections with wires using. In addition, for most users, including the advanced users it is easier to view and read the graphical programming compared with the text programming. Figure 16 illustrates the operation flow diagram of VIEM.

GND

VI

VO

SHDN

POK GND 2

5

C6 1u

4

1

IC1 +VS

VO

To ADC 2

GND

3 LM50

GND

TP5

C3 3 1u

Power GND

U2 MAX8875

AGND

1 2

1

TP2

JP2

+3V3

+5V

9

+5V

Journal of Analytical Methods in Chemistry

4

Ref.

GND

IR11BR

+3V3

LAMPR

7 +3V3

+3V3

V+

C2 1u

R3 820k

AD8628ARZ U3 TP3 3 + +VS To ADC 6 2 1u − R1 820k −VS C7 47k R4 GND 10u 6k8 R9 1u GND GND 360k R7 C11 C9 GND GND 82n

Act. Pyro C4

+3V3

4

S1 LAMP Act.

R5 820k

+3V3

2

5

0V

4 Hz sqr

SHDN POK GND

Lamp

AGND

AGND

JP1

VO

TP1

AGND

3 2 1

C1 3 1u

VI

AGND

LAMP

AGND

1

U1 MAX8875

+3V3

GND

AD8628ARZ U4 TP4 3 + 7 +VS To ADC 6 2 1u − −VS R2 820k C8 4 47k R6 10u GND 6k8 R10 GND GND 1u R8 360k C10 C12 GND 82n GND

1 2 3

Output

+3V3

Ref. Pyro C5

JP3

Figure 10: Circuit designed for CO2 signal conditioning.

4. Applications

Figure 11: Test counter programming block.

Figure 12: Programming block of the configuration window.

The main operation of the measurement system for gas emissions of internal combustion is to measure the gases concentration of O2 , NO, CO, SO2 , and CO2 , for which it uses electrochemical and infrared sensors. Sensors measure the emissions that are generated from a diesel engine that runs with diesel-biodiesel blends. The measurement is performed once the combustion gases are conducted through a pipeline. The flow is firstly conducted to an oil separator and finally to a heat exchanger. Then, the gases are conducted to an exhaust manifold, where the different outputs are connected to the sensors to meter readings in real time, register and storage data provided by the signal conditioners devices and processed through the virtual instrument in the PC. There is the versatility to meter readings every 15 and 20 seconds, as well as 1 and 5 minutes, to create a database. Other virtual instrument applications are used in monitoring stations, chemical stations, steel industries, restaurants, power stations, combined cycle, internal combustion diesel engines, gasoline, natural gas, and departments of motor testing vehicle. They represent an option for the utilization of the VIEM through its redesign and adaptation to work as a portable system. Figure 17 shows the graphical interface that virtual instrument (VIEM) provides at the moment to select the configuration option. The software enables determining the testing time, the acquisition data time, and the option to start the established tests.

10

Journal of Analytical Methods in Chemistry

Figure 13: While loop 1 programming block.

Figure 14: While loop 2 programing block.

Journal of Analytical Methods in Chemistry

11

Figure 15: Sub-VI acquisition programing block.

Start

Initial variables a1 = 0, t = 0, test = i

+

Test parameters setup

No

a1 = 1 Yes Start the acquisition signal of analog sensors

Digital signal processing

Display signals on screen

No Ongoing testing t = 0 Yes Save and export data

No End

Test = i + 1

Yes

Figure 16: Operation flow scheme of VIEM.

+

12

Journal of Analytical Methods in Chemistry It is recommended to add more sensors to the VIEM to measure a wider range of gases as well as some sensor or analyzer to measure in the order of parts per million.

Competing Interests The authors declare that they have no competing interests.

Acknowledgments Figure 17: Main window graphical user interface, tab settings.

The authors thank the National Council on Science and Technology (CONACYT) and the Engineering Institute of the Autonomous University of Baja California for its support in the development of this work.

References

Figure 18: Graphical user interface, instant tab.

Figure 19: Graphical user interface, testing tab.

Figure 18 shows the graphical user interface, where measurements can be seen in real time of O2 , NO, CO, SO2 , and CO2 gases, temperature, fuel consumption, and revolutions per minute (rpm). Figure 19 highlights the emissions measurement, temperature, rpm, and fuel consumption results. The user is able to select the running results to plot them in a graph.

5. Conclusions In this work a virtual instrument based on the LabVIEW 2010 platform was developed to measure and monitor the emissions such as O2 , NO, CO, SO2 , and CO2 from internal combustion engines that run on gasoline, diesel, or dieselbiodiesel blends. It is an open architecture instrument and user-friendly. It is possible to modify its graphical interface and include new operations, for example, sensors that measure other emissions depending on the type of concentration and pollutant volumes, according to the user needs. The VIEM is a useful tool for the emissions measurement that could be used by the industry sector and motor vehicles, as well as its use in the research and academics.

[1] Environmental Protection Agency, Light-Duty Vehicle and Light-Duty Truck—Clean Fuel Fleet Exhaust Emission Standards, EPA, 2012-2013. [2] J. Bollen and C. Brink, “Air pollution policy in Europe: quantifying the interaction with greenhouse gases and climate change policies,” Energy Economics, vol. 46, pp. 202–215, 2014. [3] R. Bosch, Automotive Handbook, Bentley Publishers, Cambridge, Mass, USA, 8th edition, 2011. [4] M. Gorji-Bandpy, S. Soleimani, and D. D. Ganji, “The effect of different injection strategies and intake conditions on the emissions characteristics in a diesel engine,” International Journal of Vehicular Technology, vol. 2009, Article ID 105363, 11 pages, 2009. [5] A. Corsini, G. Fanfarillo, F. Rispoli, and P. Venturini, “Pollutant emissions in common-rail diesel engines in extraurban cycle: rapeseed oils vs diesel fuel,” Energy Procedia, vol. 82, pp. 141– 148, 2015. [6] Emission Standards, “DieselNet: Diesel Exhaust,” 2007. [7] G. Montero, M. Stoytcheva, M. Coronado et al., “An overview of biodiesel production in Mexico,” in Biofuels—Status and Perspective, K. Biernat, Ed., chapter 19, InTech, Rijeka, Croatia, 2015. [8] M. Coronado, G. Montero, B. Valdez et al., “Degradation of nitrile rubber fuel hose by biodiesel use,” Energy, vol. 68, pp. 364–369, 2014. [9] C. V. N. Abbe, R. Nzengwa, and R. Danwe, “Comparing in cylinder pressure modelling of a DI diesel engine fuelled on alternative fuel using two tabulated chemistry approaches,” International Scholarly Research Notices, vol. 2014, Article ID 534953, 7 pages, 2014. [10] A. Nalgundwar, B. Paul, and S. K. Sharma, “Comparison of performance and emissions characteristics of DI CI engine fueled with dual biodiesel blends of palm and jatropha,” Fuel, vol. 173, pp. 172–179, 2016. [11] W. Nor Maawa Wan Ghazali, R. Mamat, H. H. Masjuki, and G. Najafi, “Effects of biodiesel from different feedstocks on engine performance and emissions: a review,” Renewable and Sustainable Energy Reviews, vol. 51, pp. 585–602, 2015. [12] Norma oficial mexicana NOM-047-ECOL-1993, http://www .dof.gob.mx/nota detalle.php?codigo=5371998&fecha=26/11/ 2014. [13] N. Clark and M. Gautam, Evaluation of Technology to Support a Heavy-Duty Diesel Vehicle Inspection and Maintenance Program, West Virginia University, Morgantown, WV, USA, 2001.

Journal of Analytical Methods in Chemistry [14] Testo, 2015, http://www.testolimited.com/testo-340-industrialflue-gas-analyser. [15] Enerac, “Portable Compliance-level Combustion Emissions Analyzer. M-700 Combustion Emissions Analyzer,” 2015, http:// www.enerac.com/enerac-700/. [16] H. Meng, J.-Y. Li, and Y.-H. Tang, “Virtual instrument for determining rate constant of second-order reaction by pX based on LabVIEW 8.0,” Journal of Automated Methods and Management in Chemistry, vol. 2009, Article ID 849704, 7 pages, 2009. [17] W.-B. Wang, J.-Y. Li, and Q.-J. Wu, “The design of a chemical virtual instrument based on LabVIEW for determining temperatures and pressures,” Journal of Automated Methods and Management in Chemistry, vol. 2007, Article ID 68143, 7 pages, 2007. [18] G. D’Ans, P. Ripak, P. Cerckel et al., Some Applications of Virtual Instrumentation in NDT, St. Genesius Rode, Belgium, 2001, http://www.ulb.ac.be/polytech/laborulb/athens/papere.pdf. [19] S. Booksh, “Virtual instrumentation,” in Proceedings of National Technical Training Symposium and 26th Annual Meeting, Pittsburgh, Pa, USA, June 2002. [20] C. E. Lenehan, N. Barnett, and S. Lewis, “Design of LabVIEWbased software for the control of sequential injection analysis instrumentation for the determination of morphine,” Journal of Automated Methods and Management in Chemistry, vol. 24, no. 4, pp. 99–103, 2002. [21] H. Goldberg, “What is virtual instrumentation?” IEEE Instrumentation & Measurement Magazine, vol. 3, no. 4, pp. 10–13, 2000. [22] P. G. Draut¸, R. Ionel, A.-S¸. Gontean, and I. Ionel, “A new approach for carbon monoxide measurement using virtual instrumentation,” in Proceedings of The 6th WSEAS International Conference on Energy, Environment, Ecosystems and Sustainable Development (EEESD ’10), pp. 267–271, Timisoara, Romania, October 2010. [23] K. Moore, Testing Automotive Exhaust Emissions, National Instruments Application Notes, National Instruments Corporation, 2013. [24] M. Branzila, “Instrumentation and virtual library for air pollution monitoring,” in Air Pollution, InTech, 2010.

13

Virtual Instrument for Emissions Measurement of Internal Combustion Engines.

The gases emissions measurement systems in internal combustion engines are strict and expensive nowadays. For this reason, a virtual instrument was de...
4MB Sizes 1 Downloads 9 Views